Loading The Firmware To The Switcher - Extron electronics SW12 VGA Ars User Manual

Computer video and audio switchers
Hide thumbs Also See for SW12 VGA Ars:
Table of Contents

Advertisement

4.
Follow the instructions on the rest of the download screens to save the
executable firmware file to your computer. Note the folder to which you save
the file.
5.
In the Windows Explorer or other file browser, locate the downloaded
executable file, and double-click on it to open it.
6.
Follow the instructions on the Installation Wizard screens to install the new
firmware on your computer. A Release Notes file, giving information on
what has changed in the new firmware version, and a set of instructions for
updating the firmware are also loaded.

Loading the firmware to the switcher

To load a new version of firmware to your SW8/12 VGA Ars switcher, use the
Firmware Loader software. Your computer's serial port must be connected to the
switcher's serial port. See chapter 2, "Installation," for more information.
1.
Download the Firmware Loader installer executable file to your
computer, as follows:
a.
On the Extron Web page, click the Download tab.
b.
On the Download Center page, click Software on the left sidebar menu.
c.
Locate the "Firmware Loader" line and click the Download link at the far
right.
d.
Follow the instructions on the download screens to save the installer file
to your computer.
2.
In the Windows Explorer or other file browser, locate the Firmware Loader
executable file in your computer's file system and double-click to open it.
3.
Follow the instructions on the Installation Wizard screens to install the
Firmware Loader on your computer. Unless you specify otherwise, the
installer program places the Firmware Loader file, "FWLoader.exe" at
c:\Program Files\Extron\FWLoader
(If the Extron and FWLoader folders do not yet exist in your Program Files
folder, the installer creates them.)
4.
Access the FWLoader.exe file via your desktop Start menu by making the
following selections:
Start > All Programs > Extron Electronics > Firmware Loader >
Firmware Loader
5.
On the first screen that appears, select the RS-232 tab.
N Although the screen also has a TCP/IP tab, the switcher does not have a LAN
port. Do not select the TCP/IP tab.
6.
From the drop-down menus on the RS-232 screen, select the appropriate Com
port number (obtained from your system administrator) and baud rate (the
default is 9600). (The Device selection is optional.)
SW8/12 VGA Ars • Control
3-7