Installation and Operation, cont'd
Figure 2-2 — Location of jumpers and DIP switches
Sync polarity jumpers
The interface is factory configured for the output sync to follow
the input sync. To force positive or negative sync, reconfigure
the jumper as follows:
1.
2.
3.
RGB 201 Rxi Universal Interface • Installation and Operation
2-4
J9
H Sync
J20 V Sync
J21 Enable
Sync
J23
Locate J9, J20, and J21 on the printed circuit board.
For sync follow (output sync polarity identical to the
input sync), ensure that the jumper is removed from
jumper block J21.
For positive or negative sync, ensure that a jumper is
installed in jumper block J21 and configure J9 and J20 as
follows:
a.
Horizontal sync —
For positive sync, install a jumper in block J9.
For negative sync, remove the jumper from block J9.
b.
Vertical sync —
For positive sync, install a jumper in block J20.
For negative sync, remove the jumper from block J20.
ON
1
2
1
1
J28
J11
J22
1
RS-232
Connector
SW2
Blue
Red
1
2
3