Instructions for the installation engineer

Installation and connection must
be done in compliance with the
regulations in force. All repairs
may only be carried out once the
appliance is turned off. Repairs
must only be carried out by
qualified service engineers.
The
manufacturer
liability in cases where safety
regulations
followed.
Connecting to the electrical supply
Before connection to the mains, please
ensure the following:
-
The fuse and the domestic electrical in-
stallation must be designed for the
max. load of the appliance (see Rating
plate).
-
The domestic electrical installation
must be equipped with a proper earth
connection in accordance with the
regulations in force.
-
The plug socket or multi-pole off
switch must be easily accessible once
the appliance has been installed.
This appliance is supplied with a con-
nection cable incorporating a standard
plug, suitable for the total electric load
shown on the rating plate. The plug is to
be inserted into a suitable wall socket.
The following connection cables are
suitable taking account of the respective
nominal profiles required:
H07RN-F, H05RN-F, H05RR-F, H05VV-F,
H05V2V2-F (T90), H05BB-F.
If the appliance is connected without a
plug, or if the plug is not accessible, a
multi-pole off switch (e.g. fuses, circuit
breaker) with a minimum gap of 3 mm
between the contacts must be installed
between the appliance and mains cable.
The switch must not interrupt the earth
wire at any point. The yellow-green earth
wire must be 2-3 cm longer than all other
cables.
The power cable must also be
designed so that at no point does it reach
50°C (above room temperature).
denies
have
not
been
Once connected, the heating elements
must be tested by being operated for about
3 minutes.
Terminal block
The oven is equipped with an easily
accessible terminal block, which is meant
for operation with a single phase voltage
all
of 230 V.
L
-
N
-
or E -
Live terminal
Neutral terminal
Earth terminal