Wireless 2-gang vibration sensor rolling ball type (11 pages)
Summary of Contents for netvox R718LB2
Page 1
This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX Technology. The specifications are subject to change without prior notice.
Table of Content 1. Introduction ......................... 2 2. Appearance ........................3 3. Main Features ......................3 4. Set up Instruction ......................4 5. Data Report ......................... 5 6. Installation ........................ 10 7. Information about Battery Passivation ..............13 7.1 To determine whether a battery requires activation.......... 13 7.2 How to activate the battery ................
1. Introduction The R718LB2 is a long-range (communication distance) Wireless 2-Gang Hall Type Open/Close Detection Sensor for Netvox Class A type devices based on the LoRaWAN open protocol, and is compatible with the LoRaWAN protocol. LoRa Wireless Technology: LoRa is a wireless communication technology famous for its long-distance transmission and low power consumption.
Configurable parameters via third-party software platform, reading data and setting alarms via SMS text and email (optional) Available for third-party platforms: Actility / ThingPark, / TTN / MyDevices / Cayenne Improved power management for longer battery life Battery Life: ⁻Please refer to web: http://www.netvox.com.tw/electric/electric_calc.html...
4. Set up Instruction On/Off Power on Insert batteries. (users may need a screwdriver to open) Press and hold the function key for 3 seconds till the green indicator flashes Turn on once. Turn off Press and hold the function key for 5 seconds till green indicator flashes for (Restore to factory setting) 20 times.
Note: The device report interval will be programmed based on the default firmware which may vary. The interval between two reports must be the minimum time. Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver http://loraresolver.netvoxcloud.com:8888/page/index to resolve uplink data.
Page 9
Example#2 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V. MaxTime Sleeping(MinTime) sleeping sleeping sleeping Wakes up and Wakes up and Wakes up and Wakes up and Wakes up and collects data collects data collects data collects data collects data 3.6V...
Page 10
(2) The data collected is compared with the last data reported. If the data change value is greater than the ReportableChange value, the device reports according to MinTime interval. If the data variation is not greater than the last data reported, the device reports according to MaxTime interval.
When the installation clearance is greater than 3cm, the device will not be able to trigger the signal. 1. The Wireless 2-gang Hall Type Open/Close 2. Tear off 3M release paper of Hall sensor and Detection Sensor (R718LB2) has a built-in the magnet then attach to the door or window magnet (see Figure 1 below).
Page 12
The Wireless 2-gang Hall Type Open/Close Detection Sensor (R718LB2) can be used in the following scenarios: Door, window Machine room door Archives Closet Refrigerators and freezers Cargo ship door Garage Door Public toilet door Where you need to detect the opening and closing status.
Page 13
If the magnet moves along the Y axis relative to the sensor, it will cause repeated reports due to the magnetic field.
7. Information about Battery Passivation Many of Netvox devices are powered by 3.6V ER14505 Li-SOCl2 (lithium-thionyl chloride) batteries that offer many advantages including low self-discharge rate and high energy density. However, primary lithium batteries like Li-SOCl2 batteries will form a passivation layer as a reaction between the lithium anode and thionyl chloride if they are in storage for a long time or if the storage temperature is too high.
8. Important Maintenance Instruction Kindly pay attention to the following in order to achieve the best maintenance of the product: • Keep the device dry. Rain, moisture, or any liquid, might contain minerals and thus corrode electronic circuits. If the device gets wet, please dry it completely. •...