Product Description
1.2.5 Electrical Specifications
Specification
Rated voltage
Input voltage range
Rated frequency range
Input frequency range
Rated current
Power consumption
Insulation resistance
Dielectric strength
1.2.6 Environmental Conditions
Table 1-8. Acceptable Environmental Conditions
Condition
Temperature
Humidity
Shock resistance
Vibration resistance
*1
: For printer operation, conditions must be in the range shown in the figure below.
*2
: These conditions are applicable when the printer is in its shipping container.
*3
: Without condensation.
Figure 1-6. Temperature / Humidity Range
1-8
Table 1-7. Rated Electrical Ranges
120 V Version
120 VAC
103.5
132 V
50
60 Hz
49.5
60.5 Hz
0.6 A
Approx. 20 W
(self-test with 10-cpi LQ characters)
10 M
minimum
(applying 500 VDC between AC line
and chassis)
1000 VAC rms - 1 minute or
1200 VAC rms - 1 second
(between AC line and chassis)
Operating
10
35 C (50
20
80% RH
1G (within 1 msec.)
0.15 G
Humidity
(% RH)
8 0 %
5 5 %
20%
(50˚ F)
220 - 240 V Version
(self-test with 10-cpi LQ characters)
10 M , minimum
(applying 500 VDC between AC line
1500 VAC rms - 1 minute
(between AC line and chassis)
Non Operating
*1
95 F)
20
60 C ( 4
*1,3
5
2G (within 2 msec.)
Guaranteed
˚ C
27˚ C 35˚ C
(˚ F)
(80˚ F) (95˚ F)
Stylus Pro XL
220 - 240 VAC
198
264 V
50
60 Hz
49.5
60.5 Hz
0.4 A
Approx. 20 W
and chassis)
*2
122 F)
*2,3
85% RH
*2
2
0.50 G
Rev.A