Upgrade Procedures For 1.1 Ghz Mx2 Dual Processor Modules (A9730A); Introduction; Required Tools; Back Up Your System - HP 9000 rp4440 Upgrade Manual

A7124a to ab383a configuration a7134a to ab383a configuration
Hide thumbs Also See for 9000 rp4440:
Table of Contents

Advertisement

3
Upgrade Procedures for 1.1 GHz mx2 Dual
Processor Modules (A9730A)

Introduction

This chapter presents procedures for installing hp 1.1 GHz mx2 dual processor modules. The server operating
system must be installed when incorporating this server upgrade. Refer to the OS documentation for update
procedures. Included are instructions to protect your data, back up the existing operating system (OS)
software (in case of an error condition during the update), download new firmware, and replace or install new
hardware. After preforming these procedures, you will be directed to start up your server and resume
operation.

Required Tools

The hp 9000 rp4440 Server Upgrade Kit contains some of the tools needed to perform this procedure,
including an ESD-safe workstation. Additionally, a long flat blade screwdriver is required. When performing
this upgrade, you must use a static-dissipating work surface and a wrist strap.

Back Up Your System

Before performing the server upgrade, protect yourself by backing up all data and your server OS. In the
event of interruptions (such as, power failure, or interference), it may be necessary to resume operation in the
old configuration before upgrading the server.
Back Up Your Data
Back up your data in accordance with local procedures.
Back Up the Operating System
Always keep a backup copy of the current operating system (OS) available for emergency use. The OS was
provided on CD with your server. You can obtain a copy from your HP-Information Resource Center (ITRC) or
download the Windows TM or HP-UX TM OS from http://www.hp.com/support/itaniumservers.
Software/Firmware Requirements
Newer versions may be available, and should be used. Download the current software and firmware at:
www.hp.com/support/itaniumservers.
Download Firmware and Shutdown the Server
To download firmware and shutdown the server, proceed as follows:
Step 1. Make sure that all users are logged off and that the server is not in use.
Step 2. Perform an orderly shutdown of the server operating system.
Step 3. Download server firmware. Current revisions of firmware and utilities, together with download
instructions are available from the ITRC and from http://www.hp.com/support/itaniumservers.
Step 4. Update the server firmware following update instructions included with the firmware.
Step 5. Press the power switch on the server front panel. Verify that the power LED goes off.
Chapter 3