CommScope ETHERSEAL 1479563-2 Instruction Sheet page 2

Receptacle kits

Advertisement

Recommended Panel or Faceplate Cutout
Note: Not to Scale
1.3. Installation
1. Slide the O-ring over the threaded portion of the receptacle. See Figure 2.
2. Insert the threaded portion of the receptacle through the front of the panel or faceplate. Orient the
receptacle in the cutout so that the white arrow indicator on the front of the receptacle is facing up.
See Figure 2.
3. From the back of the panel or faceplate, thread the nut onto the threaded portion of the receptacle.
See Figure 2. Tighten the nut to a torque of 2.26 Nm [20 in.-lb].
4. Refer to Figure 3, and insert the jack or coupler into the receptacle as follows:
a. From the back of the receptacle, align the fixed latch of the jack or coupler with the white arrow
indicator of the receptacle.
b. Tilt the back of the jack or coupler up at a slight angle, and slide it into the opening of the
receptacle. Hook the fixed latch into the slot inside the receptacle.
c. Rotate the back of the jack or coupler down so that the movable latch deflects and locks into the
receptacle.
Front of Receptacle
Fixed Latch
Jack (Ref)
2. REVISION SUMMARY
Revisions to this instruction sheet include:
Rebranded to CommScope
Rev E
25.65 mm
[1.010 in.]
⌀ 28.45 mm
[1.120 in.]
Figure 2
White Arrow Indicator
of Receptacle
Slot Inside of
Receptacle
Movable Latch
Figure 3
®
Installing Receptacle
Back of
Faceplate (Ref)
Nut
Rotate
Jack
Movable Latch
408-8875
White Arrow Indicator
of Receptacle
O-Ring
Fixed Latch
Opening of
Receptacle
2 of 2