Philips LC7.1HE LA Service Manual page 26

Table of Contents

Advertisement

EN 26
5.
LC7.1HE LA
Table 5-3 NVM editor overview
Hex
.ADR
0x000A
.VAL
0x0000
.Store
Store?
5.8.2
Load Default NVM Values
It is possible to download default values automatically into the
NVM in case a blank NVM is placed or when the NVM first 20
address contents are "FF". After the default values are
downloaded, it is possible to start-up and to start aligning the
TV set. To initiate a forced default download the following
action has to be performed:
1. Switch "off" the TV set with the mains cord disconnected
from the wall outlet (it does not matter if this is from
"Standby" or "Off" situation).
2. Short-circuit the SDM jumpers on the SSB (keep short
circuited).
3. Press "P+" or "CH+" on the local keyboard (and keep it
pressed).
4. Reconnect the mains supply to the wall outlet.
5. Release the "P+" or "CH+" when the set is "on" or blue LED
is blinking.
When the downloading has completed successfully, the set
should be into Standby, i.e. red LED on.
Alternative method (1):
1. Go to SAM.
2. Select NVM Editor.
3. Select ADR (address) to 1 (dec).
4. Change the VAL (value) to 170 (dec).
5. Store the value.
6. Do a hard reset to make sure new default values took
place.
Alternative method (2):
It is also possible to upload the default values to the NVM with
ComPair in case the SW is changed, the NVM is replaced with
a new (empty) one, or when the NVM content is corrupted.
After replacing an EEPROM (or with a defective/no EEPROM),
default settings should be used to enable the set to start-up and
allow the Service Default Mode and Service Alignment Mode to
be accessed.
5.8.3
Start-up/Shut-down Flowcharts
Important note for DVB sets:
When you put a DVB set into Stand-by mode with an RC,
the set will go to "Semi Stand-by" mode for 5 minutes. This,
to facilitate "Off the Air download" (OAD). If there is no
activity within these 5 minutes, the set will switch to Stand-
by mode. In "Semi Stand-by" mode, the LCD backlight and
Audio Amplifier are turned "off" but other circuits still work
as normal. The customer might think the set is in Stand-by.
However, in real Stand-by mode, only the uP and the NVM
are alive and all other circuits are switched "off".
If you press the mains switch at the local key board in a
DVB set, the set will switch to Stand-by mode.
On the next pages you will find start-up and shut-down
flowcharts, which might be helpful during fault finding.
It should be noted, that some events are only related to PDP
sets, and therefore not applicable to this LCD chassis.
Service Modes, Error Codes, and Fault Finding
Dec
Description
10
Existing value
0
New value

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents