CONTENT TECHNICAL DATA ............5 GENERAL INFORMATION .
Page 3
IMPORTANT SECURITY INFORMATION • This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental abilities or lack of experience and knowledge, if they have been given supervision or appropriate training regarding the use of the device in a safe way and they understand the dangers involved.
Page 4
• All repairs where required must be completed by the manufacturing company or by special authorised staff. • If the heater is sold without cable and plug or any other disconnecting method, the installer must incorporate a disconnecting device taking into account the specific regulations that apply.
Net Weight Model Size (mm) Fuse Rating Class Of Fins Rating (W) (Kg.) Avant-DGi+ 350 340 x 580 x 100 5 Amp. Avant-DGi+ 500 420 x 580 x 100 5 Amp. Avant-DGi+ 750 580 x 580 x 100 5 Amp.
Location The ideal place to site the Ducasa radiator is as close as possible to coolest wall in the room but it is not recommended to site the radiator on un-insulated exterior walls, in this case, the part of the wall behind the radiator should be insulated.
Page 7
Mounting The Radiator Place the radiator on the floor, as shown in Figure 1a. For radiators with 4, 6 and 8 elements position the brackets supplied with the radiator between the first and second element (figure 1b). For radiators with more than 9 elements, the bracket should be placed between the second and third element (figure 1b).
This may be convenient for single heaters however we recommend Gateway to control multiple heaters. The Avant DGi+ is also compatible with Amazon Alexa and Google Home via the System and App. For instructions on how to link them, visit https://ducasa.co.uk/smartcommand/voicecontrol...
To switch the radiator On again, press the MODE AUTO / MANUAL /OFF PROG button to choose programme mode or manual Ducasa DGi+ Radiator Controls mode – you will see the following screens: USING WITH SMARTCOMAND TEVOLVE APP Connecting to the smart command tevolve app...
radiator and press the settings icon where you USING WITHOUT SMARTCOMMAND TEVOLVE APP can rename it. Mode operation Your Avant DGi+ is now ready to be controlled To assist with programming the LCD screen is from the App. backlit and will stay illuminated for approximately If the Avant DGi+ has been linked to the 10 seconds after the last button is pressed.
recognises the system’s time automatically. setting by pressing OK. The advanced settings are: Adjust Programmed Temperatures C1-> Choose ºF or ºC Adjusting temperature in the following way will C2->Choose type of thermostat accuracy only effect the temperatures used for programmed C3->...
Page 12
Firmware Version (C4) By default this function is deactivated. It shows internal software installed in the electronics. To change the status of the function, press the +/- button and then press ok to confirm. Open Window detection (C5) In order to save energy, if a window opens and causes a sudden drop in temperature the heater will stop heating.
Ducasa Avant DGi+ QUICK GUIDE TO MANUAL PROGRAMMING The Avant DGi+ & Vitro-i+ radiator is programmed by using heating ‘modes’. The modes are set for each hour of the week, starting from midnight on Sunday The days are numbered 1 to 7, with 1 being Monday and 7 being Sunday The ‘modes’...
ECODESIGN TABLE Avant Avant Avant Avant Avant Avant Avant Avant Avant Models DGi+ DGi+ DGi+ DGi+ DGi+ DGi+ DGi+ DGi+ DGi+ 1000 1250 1500 1800 950 L 1425 L Heat output 0.35 0.75 1.25 0.95 1.425 Nominal heat output (P Maximum continuous heat 0.35 0.75...
MAINTENANCE AND CARE Ducasa radiators require very little maintenance. The surfaces of the radiator must not be cleaned with an abrasive product or those containing granular substances. We recommend regular cleaning with PH neutral products. In order to clean the radiator, it is recommended that the electric power is switched off.
Need help?
Do you have a question about the AVANT-DGi+ 350 and is the answer not in the manual?