Ducasa Colorado MCR Instructions For Operating And Installation

Ducasa Colorado MCR Instructions For Operating And Installation

Electric towel radiator

Advertisement

Quick Links

(Read these instructions carefully and retain for future reference)
A qualified electrician must carry out the electrical installation of this radiator. The Electrical
installation must comply with current UK regulations. Any claim on the warranty could be invalid
COLORADO MCR/TCR
Electric Towel Radiator
Instructions for Operating and Installation
MCR-40/80
MCR-40/120
MCR-40/140
TCR-140
if these requirements have not been met.
Models:
White
White
White
Chrome
NOTE:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Colorado MCR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ducasa Colorado MCR

  • Page 1 COLORADO MCR/TCR Electric Towel Radiator Instructions for Operating and Installation (Read these instructions carefully and retain for future reference) Models: MCR-40/80 White MCR-40/120 White MCR-40/140 White TCR-140 Chrome NOTE: A qualified electrician must carry out the electrical installation of this radiator. The Electrical installation must comply with current UK regulations.
  • Page 2: General Information

    Comfort, Economy, Turbo and Frost Protection settings � Overheat protection with safety cut-out � Two colour LED indicators to show operating status � Programmable by infrared remote control (Ducasa Remote) – optional � Fitted with connecting power cable 1200mm long (without a plug)
  • Page 3: Technical Data

    Technical Data MODEL MCR 40/80 MCR 40/120 MCR/40/140 TCR 140 Wattage (W) Power 230-240V/1/50Hz. 230-240V/1/50Hz. 230-240V/1/50Hz. 230-240V/1/50Hz. Weight (Kg.) 10.5 Dimensions (mm) 500 x 790 x 70 500 x 940 x 70 500 x 1400 x 70 500 x 1400 x 70 Class IP Rating Cable (mm)
  • Page 4: Installation Instructions

    INSTALLATION INSTRUCTIONS: Electrical Power Supply A qualified electrician must carry out the electrical installation of this radiator. The electrical installation must comply with current UK regulations. Any claim on the warranty could be invalid if these requirements have not been met. The radiator requires a 230/240V 50/60Hz power supply.
  • Page 5 First position the four support assemblies on the towel rail. Locate component (B) in a support position between the tubes from the back of the towel radiator and hold it in position by attaching the retaining component (D) from the front using screw (C). Repeat this in all four support positions. Now lift the towel radiator onto the wall in the desired location and press against the wall, check that it is level and then mark the position of the four supports.
  • Page 6: Use Of Controls

    OPERATING INSTRUCTIONS: MCR / TCR Towel Radiator Controller 1. Mode indicator: 2. Power indicator Green = Comfort Red= Room below set temperature (heat on) Green Flashing = Eco Mode Off = Room above set temperature (heat off) Red Flashing = Frost Protection Red = Turbo 3.
  • Page 7: Function Modes

    Control Using A Ducasa Remote Programmer (Optional) The Ducasa digital controller can be used to set all the function modes previously described. In addition to setting the heating mode it also allows 24 hour, 7 day timing and a range of features such as Holiday Programme.
  • Page 8: Maintenance And Care

    MAINTENANCE AND CARE Ducasa radiators require very little maintenance. The surfaces of the radiator must not be cleaned with an abrasive product or those containing granular substances. We recommend regular cleaning with PH neutral products. In order to clean the radiator, it is recommended that the electric power is switched off.