Ducasa AVANT–DGi+ 350 Operating And Installation Instructions
Ducasa AVANT–DGi+ 350 Operating And Installation Instructions

Ducasa AVANT–DGi+ 350 Operating And Installation Instructions

Hide thumbs Also See for AVANT–DGi+ 350:

Advertisement

Quick Links

(Read these instructions carefully and retain for future reference)
Amazon Alexa and Google Home compatible
A qualified electrician must carry out the electrical installation of this radiator. The electrical
installation must comply with current UK regulations. Any claim on the warranty could be invalid
AVANT–DGi+
Thermal Electric Radiator
Operating and Installation Instructions
Models:
AVANT-DGi+ 350
AVANT-DGi+ 500
AVANT-DGi+ 750
AVANT-DGi+ 1000
AVANT-DGi+ 1250
AVANT-DGi+ 1500
AVANT-DGi+ 1800
NOTE
if these requirements have not been met.
MODE
CONFIG.
PROG.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AVANT–DGi+ 350 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ducasa AVANT–DGi+ 350

  • Page 1 AVANT–DGi+ Thermal Electric Radiator Operating and Installation Instructions (Read these instructions carefully and retain for future reference) MODE CONFIG. PROG. Models: AVANT-DGi+ 350 AVANT-DGi+ 500 AVANT-DGi+ 750 AVANT-DGi+ 1000 AVANT-DGi+ 1250 AVANT-DGi+ 1500 AVANT-DGi+ 1800 Amazon Alexa and Google Home compatible NOTE A qualified electrician must carry out the electrical installation of this radiator.
  • Page 2: Table Of Contents

    CONTENT IMPORTANT SECURITY INFORMATION ........3 TECHNICAL DATA .
  • Page 3: Important Security Information

    IMPORTANT SECURITY INFORMATION • This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental abilities or lack of experience and knowledge, if they have been given supervision or appropriate training regarding the use of the device in a safe way and they understand the dangers involved.
  • Page 4 • All repairs where required must be completed by the manufacturing company or by special authorised staff. • If the heater is sold without cable and plug or any other disconnecting method, the installer must incorporate a disconnecting device taking into account the specific regulations that apply.
  • Page 5: Technical Data

    TECHNICAL DATA Number Of Power Net Weight MODEL Size (mm) Fuse Rating Fins Rating (W) (Kg.) Avant-DGi+ 350 340 x 580 x 100 5 Amp. Avant-DGi+ 500 420 x 580 x 100 5 Amp. Avant-DGi+ 750 580 x 580 x 100 5 Amp.
  • Page 6: Installation Instructions

    Location The ideal place to site the Ducasa radiator is as close as possible to coolest wall in the room but it is not recommended to site the radiator on un-insulated exterior walls, in this case, the part of the wall behind the radiator should be insulated.
  • Page 7 Mounting The Radiator Place the radiator on the floor, as shown in Figure 1. For radiators with 4, 6, 8 or 10 elements position the supports supplied with the radiator as shown in Figure 1. For radiators with 12 elements the supports should be positioned between the second and third elements from each end.
  • Page 8: Control Options

    This may be convenient for single heaters however we recommend tevolve app heattend the Tevolve Gateway to control multiple heaters. The Avant DGi+ is also compatible with Amazon Alexa and Google Home via the System and app. For instructions on how to link them, visit https://ducasa.co.uk/smartcommand/voicecontrol...
  • Page 9: Operating Instructions

    CONFIG programmes and continue to communicate with the AUTO / MANUAL /OFF PROG Gateway but will not heat. Ducasa DGi+ Radiator Controls To switch the radiator On again, press the MODE button to choose programme mode or manual mode – you will see the following screens:...
  • Page 10: Mode Operation

    MODE OPERATION When the temperature setup icon starts flashing, press OK to scroll through each mode. To assist with programming the LCD screen is backlit and will stay illuminated for approximately 10 seconds after the last button is pressed. When the radiator is operational and the room temperature is lower than the set temperature the heating symbol will be shown indicating that...
  • Page 11: Programming With Smart Commmand

    To select one of the advanced settings (C1 to PROGRAMMING WITH SMART COMMMAND C6) use the +/- keys and choose the required To programme your Avant DGi+ with a mode by pressing OK. The advanced settings Gateway you must pair the radiator to the Gateway. are: First you must activate the pairing/discovery mode C1->...
  • Page 12 Firmware Version (C4) By default this function is deactivated. It shows internal software installed in the electronics. To change the status of the function, press the +,- button and then press ok to confirm. Open Window detection (C5) In order to save energy, if a window opens and causes a sudden drop in temperature the heater will stop heating.
  • Page 13: Quick Guide To Manual Programming

    Ducasa Avant DGi+ QUICK GUIDE TO MANUAL PROGRAMMING The Avant DGi+ & Vitro-i+ radiator is programmed by using heating ‘modes’. The modes are set for each hour of the week, starting from midnight on Sunday The days are numbered 1 to 7, with 1 being Monday and 7 being Sunday The ‘modes’...
  • Page 14 Installation Notes:...
  • Page 15: Ecodesign Table

    ECODESIGN TABLE Avant Avant Avant Avant Avant Avant Avant Models DGi+ DGi+ DGi+ DGi+ DGi+ DGi+ DGi+ 1000 1250 1500 1800 Heat output Nominal heat output (P 0.35kW 0.5 kW 0.75 kW 1.0 kW 1.25 kW 1.5 kW 1.8 kW Maximum continuous heat output 0.35kW 0.5 kW 0.75 kW 1.0 kW 1.25 kW 1.5 kW 1.8 kW...
  • Page 16: Maintenance And Care

    MAINTENANCE AND CARE Ducasa radiators require very little maintenance. The surfaces of the radiator must not be cleaned with an abrasive product or those containing granular substances. We recommend regular cleaning with PH neutral products. In order to clean the radiator, it is recommended that the electric power is switched off.