38AP UNIT SIZES
NOMINAL CAPACITY 50/60 Hz (kW)
CIRCUIT
OPERATING WEIGHTS (kg)
Standard
With Low Sound Option
APPROXIMATE REFRIGERANT CHARGE,
TYPICAL (kg)*
NITROGEN SHIPPING CHARGE
COMPRESSOR
kW (Qty) (CKT A/CKT B)
CAPACITY STEPS
Standard
Digital Option
CRANKCASE HEATER (W) (each compressor)
CONDENSER FANS
Standard
Quantity
r/s
Diameter (mm)
Total Watts (60 Hz)
Total Watts (50 Hz)
Low Noise
Quantity
r/s
Diameter (mm)
Total Watts (60 Hz)
Total Watts (50 Hz)
CONDENSER COIL
No. Coils per Circuit
sq m
TEMPERATURE RELIEF
CONNECTIONS (in.) ODF (CKT A/CKT B)
Suction Line
Liquid Line
MAXIMUM HEIGHT FOR 1.7° C
SUBCOOLING (m)†
CAPACITY PER CIRCUIT (%) (CKT A/CKT B)
MINIMUM UNIT CAPACITY (%)
LEGEND
MCHX —
Microchannel Heat Exchanger
ODF
Outside Diameter, Female
*Typical operating charge with 7.62 m of interconnecting piping. Operating
charge is approximate for maximum system capacity. Unit is factory supplied
with nitrogen holding charge. Refrigerant charge for dual circuit units is the
total for both circuits.
†Maximum vertical separation between evaporator coil and condensing unit if
condensing unit is below the evaporator.
Table 3 — 38AP025-050 Unit Physical Data — SI
025
027
74/88
81/95
Dual
Single
Dual
497
489
571
513
505
587
12.7
10.9
13.6
8.2 (2)
8.2 (2)
9.7 (2)
2
2
2
22
22
22
2
2
2
3300
3300
3300
2750
2750
2750
2
2
2
2750
2750
2750
2300
2300
2300
2.5
2.5
3.2
1
3
/
/ 1
3
/
1
5
/
1
3
/
/ 1
3
/
8
8
8
8
8
5
/
/
5
/
5
/
5
/
/
5
/
8
8
8
8
8
23
23
23
50/50
100
50/50
50
50
50
030
88/106
Single
Dual
Single
562
573
565
579
590
582
11.8
13.6
11.8
1.03 bar
9.7 (2)
11.2 (2)
11.2 (2)
2
2
2
22
22
22
90
Propeller Type - Direct Drive
2
2
2
19 (60 Hz), 16 (50 Hz)
762
3300
3300
3300
2750
2750
2750
Shrouded Axial Fan - Direct Drive
2
2
2
14 (60 Hz), 12 (50 Hz)
762
2750
2750
2750
2300
2300
2300
MCHX Type
1
3.2
3.2
3.2
Fusible Plug on Liquid Lines of Each Circuit - 99 C
1
5
/
1
3
/
/ 1
3
/
1
5
/
8
8
8
8
5
/
5
/
/
5
/
7
/
8
8
8
8
23
23
23
100
50/50
100
50
50
50
5
040
050
116/141
148/176
Dual
Single
Dual
950
893
961
974
917
986
23.6
18.1
23.6
7.5 (2)/
9.7 (3)
8.2 (2)/
6.3 (2)
9.7 (2)
4
3
4
44
33
44
3
3
3
4200
4200
4200
3500
3500
3500
3
3
3
3500
3500
3500
2900
2900
2900
1
6.3
6.3
6.3
1
5
/
/ 1
5
/
2
1
/
1
5
/
/ 1
5
/
8
8
8
8
8
5
/
/
5
/
7
/
5
/
/
5
/
8
8
8
8
8
23
23
23
54/46
100
48/52
23
33
23
Single
897
921
18.1
11.2 (3)
3
33
3
4200
3500
3
3500
2900
6.3
2
1
/
8
7
/
8
23
100
33

Hide quick links: