Carrier GEMINI SELECT 38APD025-100 Installation Instructions Manual page 31

Air-cooled condensing units with puron refrigerant (r-410a) 50/60 hz
Hide thumbs Also See for GEMINI SELECT 38APD025-100:
Table of Contents

Advertisement

38APS UNIT
V-Ph-Hz
SIZE
208/230-3-60
380-3-60
025
460-3-60
575-3-60
380/415-3-50
208/230-3-60
380-3-60
027
460-3-60
575-3-60
380/415-3-50
208/230-3-60
380-3-60
030
460-3-60
575-3-60
380/415-3-50
208/230-3-60
380-3-60
040
460-3-60
575-3-60
380/415-3-50
208/230-3-60
380-3-60
050
460-3-60
575-3-60
380/415-3-50
38APS UNIT
V-Ph-Hz
SIZE
208/230-3-60
380-3-60
025
460-3-60
575-3-60
380/415-3-50
208/230-3-60
380-3-60
027
460-3-60
575-3-60
380/415-3-50
208/230-3-60
380-3-60
030
460-3-60
575-3-60
380/415-3-50
208/230-3-60
380-3-60
040
460-3-60
575-3-60
380/415-3-50
208/230-3-60
380-3-60
050
460-3-60
575-3-60
380/415-3-50
LEGEND
FLA
— Full Load Amps
ICF
— Maximum Instantaneous Current Flow
LRA
— Locked Rotor Amps
MCA
— Minimum Circuit Amps
MOCP — Maximum Overcurrent Protection
RLA
— Rated Load Amps
NOTES:
1. Units are suitable for use on electrical systems where voltage supplied to
the unit terminals is not below or above the listed minimum and maximum
limits. Maximum allowable phase imbalance is: voltage 2%; amps 10%.
2. All units or modules have single point primary power connection. Main
power must be supplied from a field-supplied disconnect.
3. For MCA that is less than or equal to 380 amps, 3 conductors are
required.
For MCA between 381 and 760 amps, 6 conductors are required.
Calculation of conductors required is based on 75 C copper wire.
Table 9 — 38APS Standard Condenser Fan Electrical Data
SUPPLY
COMPRESSOR
VOLTAGE
Min
Max
Qty
RLA
187
254
48.1
342
418
23.7
414
506
2
18.6
518
632
14.7
342
440
18.6
187
254
51.3
342
418
26.9
414
506
2
23.1
518
632
19.9
342
440
23.1
187
254
55.8
342
418
34.0
414
506
2
26.9
518
632
23.7
342
440
26.9
187
254
51.3
342
418
26.9
414
506
3
23.1
518
632
19.9
342
440
23.1
187
254
55.8
342
418
34.0
414
506
3
26.9
518
632
23.7
342
440
26.9
Table 10 — 38APS Low Sound Condenser Fan Electrical Data
SUPPLY
COMPRESSOR
VOLTAGE
Min
Max
Qty
RLA
187
254
48.1
342
418
23.7
414
506
2
18.6
518
632
14.7
342
440
18.6
187
254
51.3
342
418
26.9
414
506
2
23.1
518
632
19.9
342
440
23.1
187
254
55.8
342
418
34.0
414
506
2
26.9
518
632
23.7
342
440
26.9
187
254
51.3
342
418
26.9
414
506
3
23.1
518
632
19.9
342
440
23.1
187
254
55.8
342
418
34.0
414
506
3
26.9
518
632
23.7
342
440
26.9
CONDENSER FAN
LRA
Total Qty
FLA
245
6.6
145
3.9
125
2
3.3
100
2.6
118
3.3
300
6.6
139
3.9
150
2
3.3
109
2.6
140
3.3
340
6.6
196
3.9
179
2
3.3
132
2.6
174
3.3
300
6.6
139
3.9
150
3
3.3
109
2.6
140
3.3
340
6.6
196
3.9
179
3
3.3
132
2.6
174
3.3
CONDENSER FAN
LRA
Total Qty
FLA
245
6.0
145
3.9
125
2
2.9
100
2.4
118
2.9
300
6.0
139
3.9
150
2
2.9
109
2.4
140
2.9
340
6.0
196
3.9
179
2
2.9
132
2.4
174
2.9
300
6.0
139
3.9
150
3
2.9
109
2.4
140
2.9
340
6.0
196
3.9
179
3
2.9
132
2.4
174
2.9
4. Wiring for main field supply must be rated 75 C. Use copper conductors
only.
a. Incoming wire size range for terminal block with MCA up to 175 amps is
14 AWG (American Wire Gage) to 2/0.
b. Incoming wire size range for terminal block with MCA from 175.1 amps
to 420 amps is 2 AWG to 600 kcmil.
c. Incoming wire size range for non-fused disconnect with MCA up to
100 amps is 14 AWG to 1/0.
d. Incoming wire size range for non-fused disconnect with MCA from
100.1 amp to 200 amps is 6 AWG to 350 kcmil.
e. Incoming wire size range for non-fused disconnect with MCA from
200.1 amp to 450 amps is 3/0 to 500 kcmil.
31
REC
MCA
MOCP
FUSE
121.4
150
150
61.1
80
70
48.5
60
60
38.3
50
45
48.5
60
60
128.6
175
150
68.3
90
80
58.6
80
70
50.0
60
60
58.6
80
70
138.8
175
175
84.3
110
100
67.1
90
80
58.5
80
70
67.1
90
80
186.5
225
200
99.1
125
110
85.0
100
100
72.5
90
80
85.0
100
100
201.2
250
225
122.2
150
150
97.3
110
110
84.8
100
100
97.3
110
110
REC
MCA
MOCP
FUSE
120.2
150
150
61.1
80
70
47.7
60
60
37.9
50
45
47.7
60
60
127.4
175
150
68.3
90
80
57.8
80
70
49.6
60
60
57.8
80
70
137.6
175
175
84.3
110
100
66.3
90
80
58.1
80
70
66.3
90
80
184.7
225
200
99.1
125
110
83.8
100
100
71.9
90
80
83.8
100
100
199.4
250
225
122.2
150
150
96.1
110
110
84.2
100
100
96.1
110
110
ICF
306.3
176.5
150.2
119.9
143.2
364.5
173.7
179.7
134.1
169.7
409.0
237.8
212.5
160.9
207.5
422.4
204.5
206.1
156.6
196.1
471.4
275.7
242.7
187.2
237.7
ICF
305.1
176.5
149.4
119.5
142.4
363.3
173.7
178.9
133.7
168.9
407.8
237.8
211.7
160.5
206.7
420.6
204.5
204.9
156.0
194.9
469.6
275.7
241.5
186.6
236.5