38AP UNIT SIZE
NOMINAL CAPACITY, 50/60Hz (tons)
CIRCUIT
OPERATING WEIGHTS (lb)
Standard
With Low Sound Option
APPROXIMATE REFRIGERANT CHARGE,
TYPICAL (lb)*
NITROGEN SHIPPING CHARGE
COMPRESSOR
hp (Qty) (CKT A/CKT B)
CAPACITY STEPS
Standard
Digital Option
CRANKCASE HEATER (W) (each compressor)
CONDENSER FANS
Standard
Quantity
RPM
Diameter (in.)
Total Watts (60 Hz)
Total Watts (50 Hz)
Low Noise
Quantity
RPM
Diameter (in.)
Total Watts (60 Hz)
Total Watts (50 Hz)
CONDENSER COIL
No. Coils per Circuit
sq ft
TEMPERATURE RELIEF
CONNECTIONS (in.) ODF (CKT A/CKT B)
Suction Line
Liquid Line
MAXIMUM HEIGHT FOR 3° F SUBCOOLING
(ft)†
CAPACITY PER CIRCUIT (%) (CKT A/CKT B)
MINIMUM UNIT CAPACITY (%)
LEGEND
MCHX —
Microchannel Heat Exchanger
ODF
Outside Diameter, Female
*Typical operating charge with 25 ft of interconnecting piping. Operating
charge is approximate for maximum system capacity. Unit is factory supplied
with nitrogen holding charge. Refrigerant charge for dual circuit units is the
total for both circuits.
†Maximum vertical separation between evaporator coil and condensing unit if
condensing unit is below the evaporator.
Table 1 — 38AP025-050 Unit Physical Data — English
025
21/25
Dual
Single
Dual
1095
1077
1258
1131
1113
1294
28
24
30
11 (2)
11 (2)
13 (2)
2
2
2
22
22
22
2
2
2
3300
3300
3300
2750
2750
2750
2
2
2
2750
2750
2750
2300
2300
2300
27.1
27.1
33.9
1
3
/
/ 1
3
/
1
5
/
1
3
/
/ 1
8
8
8
8
5
/
/
5
/
5
/
5
/
/
8
8
8
8
75
75
75
50/50
100
50/50
50
50
50
027
030
23/27
25/30
Single
Dual
Single
1240
1264
1246
1276
1300
1282
26
30
26
15 psig
13 (2)
15 (2)
15 (2)
2
2
2
22
22
22
90
Propeller Type - Direct Drive
2
2
2
1140 (60 Hz), 950 (50 Hz)
30
3300
3300
3300
2750
2750
2750
Shrouded Axial Fan - Direct Drive
2
2
2
850 (60 Hz), 700 (50 Hz)
30
2750
2750
2750
2300
2300
2300
MCHX Type
1
33.9
33.9
33.9
Fusible Plug on Liquid Lines of Each Circuit - 210 F
3
/
1
5
/
1
3
/
/ 1
3
/
1
5
/
8
8
8
8
8
5
/
5
/
5
/
/
5
/
7
/
8
8
8
8
8
75
75
75
100
50/50
100
50
50
50
3
040
050
33/40
42/50
Dual
Single
Dual
2094
1968
2120
2148
2022
2174
52
40
52
10 (2)/
13 (3)
11 (2)/
8.5 (2)
13 (2)
4
3
4
44
33
44
3
3
3
4200
4200
4200
3500
3500
3500
3
3
3
3500
3500
3500
2900
2900
2900
1
67.8
67.8
67.8
1
5
/
/ 1
5
/
2
1
/
1
5
/
/ 1
5
/
8
8
8
8
8
5
/
/
5
/
7
/
5
/
/
5
/
8
8
8
8
8
75
75
75
54/46
100
48/52
23
33
23
Single
1977
2031
40
15 (3)
3
33
3
4200
3500
3
3500
2900
67.8
2
1
/
8
7
/
8
75
100
33

Hide quick links: