SAFETY FIRST IMPORTANT: PLEASE READ THIS MANUAL AND SAVE FOR FUTURE REFERENCE WARNINGS: Electrical Shock Hazard Electrical Shock Hazard • Use caution when dealing with any electrical equipment. • Use caution around water. • All electrical equipment must be Ground fault/leakage current protected. Use of a Ground fault protective device (GFI, RCD, RCBB, or RCBO type device) is required as directed by local and national codes.
The RobustAire™ Diffuser should now be seated properly on the bottom of the pond. You can remove the rope by pulling on one end. For ease of future maintenance, Kasco recommends leaving the rope looped through diffuser base and tying both ends to a marker buoy or duck decoy. This will allow you to easily locate diffusers and pull them to the surface for maintenance.
THIS DRAWING CONTAINS PROPRIETARY THIRD ANGLE PROJECTION INFORMATION AND SHALL NOT BE USED, TITLE: SCALE: 1:8 SHEET 2 OF 2 REPRODUCED OR DISTRIBUTED WITHOUT SMALL RA CABINET THE PRIOR WRITTEN CONSENT OF KASCO MARINE, INCORPORATED ROBUSTAIRE SMALL CABINET SYSTEM MANUAL...
COMPRESSOR REMOVAL Remove the lid of the cabinet. Reach under Tilt lid forward to remove. the lip on the back of the cabinet and pull the outside edge of the toggle latch down to loosen. BACK Disconnect the exhaust tubing. Disconnect electrical plugs.
Page 7
COMPRESSOR REMOVAL (CONT.) Disconnect the filter minder tubing. Disconnect intake tubing from the compressor. Place the compressor upsidedown on a flat Using an 11mm wrench, remove the four surface so it is resting on the compressor head. compressor bolts from the panel. Lift panel off the compressor.
Sunny days are preferable to cloudy days for system start-up, since photosynthesis will supplement oxygen levels as the water is mixed. If you have questions about this procedure, please contact your distributor or e-mail Kasco Customer Service at support@kascomarine.com.
FILTER MAINTENANCE Warning! Product surfaces become very hot during operation. Allow compressor to cool before servicing. Disconnect electrical power before performing maintenance. Filter minder Clean filter Dirty filter (clear) (red) • Check filter monthly. • Clean or replace intake filter when filter minder shows a red band.
The compressor may be due for a rebuild. “The compressor stops and restarts” • Ensure the fan is working properly. Capacitor may need replacement. Please contact Kasco or your distributor if any problems persist. ROBUSTAIRE SMALL CABINET SYSTEM MANUAL...
Center. You can also email Kasco at support@kascomarine.com. Please include the repair form received from Kasco or your local distributor with the shipment. If no repair form is available, include your name and physical address for return delivery of the repaired unit and a day- time phone number and/or email address for correspondence regarding the warranty claim.
Please ship according to the instructions provided. Kasco does estimates on repairs at the request of the customer. The request for an estimate should be included in the letter that accompanies the returned unit and must include a daytime phone number and/or email address.
REPAIR CONTACT FORM • Kasco requires that all equipment sent for repair MUST be accompanied by this form and marked to Repairs attention. Kasco Marine • Unit should be cleaned before shipping. 800 Deere Road • Kasco is NOT responsible for shipping damage accrued in Prescott, WI 54021 return shipment.
Need help?
Do you have a question about the RobustAire RAE1 and is the answer not in the manual?