ComfortZone RX35/RX50/RX65

22 Technical data

ComfortZone Excellence
Heat pump output out / in at 45 ° C
Heat pump power out / in at 35 ° C
Max heat output
Auxiliary heater
Fan, rated power / rated current
Refrigerant R32
Air flow at 150 Pa
Nominal flow circulation water (20kPa)
Minimum flow of circulation water
Tank capacity
Sound power level
Spigots
Voltage
Fusing
Cable outdoor sensor
5-50 meters, twisted pair cable.
Expansion vessel
Preset pressure
IP-klass
Height, tall models
Height, low models
Width
Depth
Weight, tall model
Weight, low model
RX35
3,5/1,1 kW
3,3/0,9 kW
9,5 kW
6,0 kW
40W/0,40A
950 g
75-150 m³/h
6-33 l/min
3 l/min
170 l
39 dB (A)
125 mm
230V-1-phase
230V-1-phase
50Hz
50Hz
(400V-3-phase)
(400V-3-phase)
16-40A/230V
(16A/3x400V)
Min 0,25 mm²
12 L
1,0 bar
IP21
2100 mm
1600 mm
600 mm
650 mm
210 kg
175 kg
63
Service & Maintenance
RX50
4,8/1,6 kW
4,6/1,4 kW
11,0 kW
6,0 kW
75W/0,68A
950 g
100-230 m³/h
8-33 l/min
3 l/min
170 l
46 dB (A)
125 mm
230V-1-phase
50Hz
(400V-3-phase)
16-40A/230V
16-50A/230V
(16A/3x400V)
(16A/3x400V)
Min 0,25 mm²
12 L
1,0 bar
IP21
2100 mm
1600 mm
600 mm
650 mm
210 kg
175 kg
RX65
6,2/2,1 kW
6,0/1,8 kW
12,5 kW
6,0 kW
83W/0,75A
950 g
100-330 m³/h
10-33 l/min
3 l/min
170 l
48 dB (A)
160 mm
Min 0,25 mm²
12 L
1,0 bar
IP21
2100 mm
1600 mm
600 mm
650 mm
210 kg
175 kg