11 Settings during installation

Note! This section
not be carried out by the house owner.
Installation settings must be made in the menu
"Advanced settings".
Turn the knob to "Advanced settings" / "General
settings", press and hold the button for 5 seconds. Then
the installer menu opens and all selections are
available.

11.1 Basic Settings

Proceed to "/ Basic installation /". This is a shortcut
menu where the parameters that are normally set
during installation are collected. All of these are also
available under their respective submenus together with
other less commonly used parameters.
11.1.1
CW Heating mode
Options: Floor or Radiator.
Here you choose which type of heating form is desired
11.1.2
CW Control mode
Options: OUT, OUT and IN or IN.
Here you choose if you want to control the
indoor temperature via the output, output &
input sensor or input sensor. See 14.2 Choice
of regulation.
11.1.3
CW Heating Curve
Options: 1 - 10.
Here you select the appropriate heating
curve based on the table, see section
14.1.
Default: Underfloor heat= 3
Radiator = 7
NOTE: When "UV control method IN" is used, the
"UV heating curve" function goes out and is not
visible in the display.
11.1.4
CW Pump Speed
Options: 30 - 100%.
Here you select the appropriate speed for the
circulation pump.
See 17. Pump diagram.
11.1.5
Fan normal speed
Options: 0 - 100%.
Here you select the appropriate speed for the
fan. See 18. Fan Chart.