Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
ComfortZone Manuals
Heat Pump
RX35
User and installation manual
ComfortZone RX35 User And Installation Manual
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
page
of
66
Go
/
66
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Table of Contents
Panel and Control Unit
Settings During Operation
Display
Setting Temperature Control
Extra Hot Water
Temperature/Time
Control Method out & in (Factory Setting)
Control Method out
Control Method in
Indoor Temperature with Double Heat Curves
Restriction of Electrical Elements
Hot Water Temperature
Restriction of Hot Water Temperature
Hot Water Priority
Min Return Temperature / Min Inlet Temperature
Holiday Settings
Diode List
Fan Control and Timer
Smart Control
Summer Mode
Synchronization with Solar Panels
Maintenance
Main Fuse
Replacement of Air Filter
Filter Alarm Reset
Checking the System Pressure
Expansion Vessel
Electronic Galvanic Anode
Component List
Installation
Transport and Handling
Placement
Dimensions and Outlet of Ventilation Connection
Dimensions and Position of Pipe Connection RX35 / 50/65 High Model
Dimensions and Position of Pipe Connection RX35 / 50/65 - Low Model
Pipe Connections
Radiator System
Floor Heating System
Radiator and Floor Heating System
Connection Without Supply Air Unit (Standard Connection)
Connection with Supply Air Units
Minimum Circulation Flow
Connection of Extra Hot Water Tank - High Model
Connection of Hot Water Tank - Low Model
Ventilation Connection
Silencing
Adjustment of Ventilation
Electrical Connection
Power Supply 1X230V
Connection Option 3X400V
Accessories / Additional Equipment
Indoor Temperature Sensor / External Room Sensor
Connection of Outdoor Sensor
Connection of Accessories
External Alarm Output (Relay)
Accessories / Spare Parts
Commissioning
Re-Filling the System
Venting the System
Venting of Hot Water Tank
Draining / Emptying the System
Emptying the Heating Circuit
Adjusting the System
Adjustment of Shunt Groups
Adjustment of Floor Loops
Adjustment of Radiators
Settings During Installation
Basic Settings
Choice of Regulation
Blocking of Interfering Resonances
Maximum Frequency of the Compressor
Legionella Elimination
Operation with Heat Elements Only
Operation with Fan off
Start-Up and Installation Control
Adjustable HW Overheating Limit
Double Heat Curves
External Mixing Valve Control
Synchronization with Solar Panels
Troubleshooting
No Heat to the Elements (Circulation Water) Although the Compressor Is Running
The Heat Pump Heats up the HW Tank and then Stops
Overheated Auxiliary Heater - Smell of Burnt Rubber
Poor Hot Water Capacity
The Heat Pump Completely Shuts down and Does Not Start
Overheating Protection Cannot be Restored
Alarms
Filter Change Alarm
High Gas Pressure Alarm
Low Pressure Alarm 1
Low Pressure Alarm 2
Inverter Alarm (0)
Heater Overheat Alarm
Hot Water Overheat Alarm
Sensor Fault TE0-TE2
Defrost Alarm
Unknown HP Box Alarm
Heating Overheat Alarm
Heating Limitation Alarm
Heating Return Max Alarm
SD Memory Card Error
Inverter Connection Failure
Pressure Ratio Alarm
Hot Gas Temperature Alarm
Alarm - Multiple Alarms Simultaneously
EEV Min Pos Time out Alarm
EEV Max Pos Timeout Alarm
Clock Not Set Alarm
Condenser Temperature Alarm
Room under Heat Alarm
Room Overheat Alarm
Defrost Error Alarm
Heating Minimum Alarm
Heating Freez.danger Alarm
Invalid Controller Type/Version
PL1 Input Alarm
Sensor Mismatch Error TE1-TE2, TE2-TE5, TE1-TE5
No Compressor Function Error
Pump Diagram
Fan Chart
System Overview RX35 / RX50 / RX65
Wiring RX35/RX50/RX65
Connection Terminals and Fuses
Connection to Auxiliary Heater X9
Components
CE Declaration
Energy Declaration
Technical Data
Installation Protocol
Advertisement
Quick Links
1
Table of Contents
2
Setting Temperature Control
Download this manual
User and
Installation Manual
RX35 - RX50 - RX65
2020-10-30
From SW 2.0
CZ06525 Ver J
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the RX35 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for ComfortZone RX35
Heat Pump ComfortZone RX50 User And Installation Manual
(66 pages)
Heat Pump ComfortZone RX65 User And Installation Manual
(66 pages)
Heat Pump ComfortZone RXC35 User And Installation Manual
Exhaust air heat pump (56 pages)
Heat Pump ComfortZone RXC50 User And Installation Manual
Exhaust air heat pump (56 pages)
Heat Pump ComfortZone RXC65 User And Installation Manual
Exhaust air heat pump (56 pages)
This manual is also suitable for:
Rx50
Rx65
Table of Contents
Save PDF
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the RX35 and is the answer not in the manual?
Questions and answers