ComfortZone RX35/RX50/RX65

5 Installation

5.1 Transport and handling

The ComfortZone RX35 / RX50 / RX65 must always be transported standing. It
should always be stored in a dry and frost-free space.
The heat pump contains refrigerant and should therefore be handled with the
utmost care to minimize the risk of leakage.

5.2 Placement

The heat pump must be placed in a wet room with a floor drain in the event of a
leak. The heat pump is preferably placed on the ground floor next to the outer wall
or a well insulated partition wall. The heat pump should not be placed against the
bedroom wall.
If the heat pump is placed upstairs or on wooden beams, sound insulation must be
performed extra carefully, vibrated rubber feet are recommended (included in the
delivery).
The walls of the installation space shall have double plaster boards on both sides
and shall be completely filled with rock wool, or have corresponding sound
insulation, i. R'w = 44 dB.
The ceiling of the installation room shall have the structure insulated with stone wool
to full thickness.
The heat pump should be free, with a distance of at least 10 mm from the wall and
other fixed furnishing.
If the upper cabinet is mounted, this must have at least 2 mm air gap for the ceiling
or other fixed fittings.
Minimum ceiling height of 2350 mm is required for the ventilation connection.
To raise the heat pump to a standing position, 2200 mm is required.
There must be a free space of 800 mm in front of the machine for service and
maintenance, when placed in corner 1000 mm.
24
19
service & maintenance