Summary of Contents for Champion Power Equipment 201054
Page 1
This product meets the requirements of the PGMA (Portable Generator Manufacturers’ Association) standard ANSI/PGMA G300-2018 (Safety and Performance of Portable Generators). Covered by one or more of the following U.S. Patent Numbers: 10,107,207, 10,862,414 and other U.S. and foreign patents REV 20210820 Champion Power Equipment, Inc., Santa Fe Springs, CA USA...
Page 2
CARBON MONOXIDE SAFETY: THE BIG PICTURE As the only safe way to use a portable generator, taking your generator outside is absolutely mandatory to keep your family safe from carbon monoxide. But there’s even more you can do. By educating yourself about all carbon monoxide risks, you’ll be better prepared to protect your family from this colorless, oderless threat.
TAbLE OF CONTENTS 201054 - 4500W WIRELESS START OPEN FRAME INVERTER TAbLE OF CONTENTS Stopping the Engine ..........Moving the Generator ..........Introduction ...........
INTRODUCTION 201054 - 4500W WIRELESS START OPEN FRAME INVERTER INTRODUCTION SAFETY DEFINITIONS Congratulations on your purchase of a Champion Power Equipment The purpose of safety symbols is to attract your attention to possible dangers. The safety symbols, and their explanations, (CPE) product.
IMPORTANT SAFETY INSTRUCTIONS 201054 - 4500W WIRELESS START OPEN FRAME INVERTER IMPORTANT SAFETY INSTRUCTIONS DANGER Operate equipment with guards in place. WARNING Rotating parts can entangle hands, feet, hair, clothing and/or Cancer and Reproductive Harm – www.P65Warnings.ca.gov accessories. Traumatic amputation or severe laceration can result.
Page 6
IMPORTANT SAFETY INSTRUCTIONS 201054 - 4500W WIRELESS START OPEN FRAME INVERTER WARNING CAUTION Spark from removed spark plug wire can result in fire or Improper treatment or use of the generator can damage it, electrical shock. shorten its life or void the warranty.
IMPORTANT SAFETY INSTRUCTIONS 201054 - 4500W WIRELESS START OPEN FRAME INVERTER Fuel Safety When operating the generator: DO NOT move or tip the generator during operation. DANGER When transporting or servicing the generator: GASOLINE AND GASOLINE VAPORS ARE HIGHLY Always check that the fuel valve is in the OFF position and the FLAMMABLE AND EXPLOSIVE.
AUTOMATIC SHUTOFF – YOU MUST: APAGADO AUTOMÁTICO – USTED DEBE: This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for ARRÊT AUTOMATIQUE – VOUS DEVEZ : POINT AWAY outside parties without the explicit consent of Champion Power Equipment.
IMPORTANT SAFETY INSTRUCTIONS 201054 - 4500W WIRELESS START OPEN FRAME INVERTER Safety Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
IMPORTANT SAFETY INSTRUCTIONS 201054 - 4500W WIRELESS START OPEN FRAME INVERTER Operation Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
2mm safe margin; to be printed on white substrate 1. Check oil level. This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for outside parties without the explicit consent of Champion Power Equipment.
CONTROLS AND FEATURES 201054 - 4500W WIRELESS START OPEN FRAME INVERTER CONTROLS AND FEATURES Read this operator’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference.
CONTROLS AND FEATURES 201054 - 4500W WIRELESS START OPEN FRAME INVERTER Control Panel 1. Fuel Dial – Used to start and stop. RECEPTACLES 2. Intelligauge with Power Meter – Four mode digital meter 12V DC, 8A (Regulated Automotive) for displaying run time, total time, voltage, hertz and power May be used to supply electrical power for output.
CONTROLS AND FEATURES 201054 - 4500W WIRELESS START OPEN FRAME INVERTER Intelligauge with Power Meter and CO Shield The meter is divided into two separate displays. The LCD displays each mode for several seconds and then automatically cycles through. The Power Meter LED displays output in percent (%) with 100% at the top.
CONTROLS AND FEATURES 201054 - 4500W WIRELESS START OPEN FRAME INVERTER Wireless Remote Control FCC Statement for Remote Control Device This generator is equipped with a wireless remote control system 1. This device complies with Part 15 of the FCC Rules. Operation for starting and stopping.
CONTROLS AND FEATURES 201054 - 4500W WIRELESS START OPEN FRAME INVERTER Parts Included Accessories Engine Oil ........20.3 fl. oz. (600 ml) Oil Funnel .
ASSEMbLY 201054 - 4500W WIRELESS START OPEN FRAME INVERTER ASSEMbLY Install the Wheel Kit Your generator requires some assembly. This unit ships from our CAUTION factory without oil. It must be properly serviced with fuel and oil before operation.
ASSEMbLY 201054 - 4500W WIRELESS START OPEN FRAME INVERTER Connect the battery 2. Attach the support leg (E) to the generator frame with flange lock nuts (F). 1. Cut cable tie on each side of battery connector. 2. Push two halves of battery connector together tightly.
ASSEMbLY 201054 - 4500W WIRELESS START OPEN FRAME INVERTER 1. Place the generator on a flat, level surface. NOTICE 2. Remove oil fill cap/dipstick to add oil. The first 5 hours of run time are the break-in period for the 3.
ASSEMbLY 201054 - 4500W WIRELESS START OPEN FRAME INVERTER NOTICE The generator engine works well with 10% or less ethanol blended gasoline. When using ethanol-gasoline blends there are some issues worth noting: – Ethanol-gasoline blends can absorb more water than gasoline alone.
LED light in the CO Shield area provides notification This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for other fuel burning sources such as engine powered tools, or outside parties without the explicit consent of Champion Power Equipment.
OPERATION 201054 - 4500W WIRELESS START OPEN FRAME INVERTER WARNING WARNING Tampering with the CO Shield® system could result in a During operation the muffler and exhaust fumes will become hazardous condition and will void your warranty. hot. If adequate cooling and breathing space are not supplied,...
Page 23
OPERATION 201054 - 4500W WIRELESS START OPEN FRAME INVERTER 2. Press the Start/Stop button to enter standby mode. 5. Push and release the “START” a button on the remote key fob. The green LEDs on the remote key fob and the Start/Stop button will blink once simultaneously to indicate the remote has been programmed.”...
OPERATION 201054 - 4500W WIRELESS START OPEN FRAME INVERTER Starting the Engine NOTICE Make certain the generator is on a flat, level surface. If CO Shield detects elevated levels of CO gas resulting in Wireless Remote Start the generator shutting down, Wireless Remote starting will become disabled and will not be able to restart the generator.
OPERATION 201054 - 4500W WIRELESS START OPEN FRAME INVERTER 4. Press the Start/Stop button to start the engine. If engine does 5. Pull the recoil cord slowly until resistance is felt and then pull not start, wait at least ten seconds before attempting to start rapidly.
OPERATION 201054 - 4500W WIRELESS START OPEN FRAME INVERTER 3. Turn the fuel dial to the “ON” position. NOTICE For gasoline manual starting in standard ambient temperature >59°F (15°C): Keep fuel dial in “CHOKE” position for three pulls of the recoil cord. If generator does not start after three pulls, rotate the fuel dial to the “RUN”...
OPERATION 201054 - 4500W WIRELESS START OPEN FRAME INVERTER WARNING Always remember to plug your appliances directly into the generator and do not plug the generator power cord into any electrical outlet or connect to the circuit breaker panel in your home.
201054 - 4500W WIRELESS START OPEN FRAME INVERTER Parallel Operation CAUTION The Champion model 201054 is parallel ready and can be For periods of high electrical load or momentary fluctuations, operated in parallel with another Champion unit to increase the the Eco Mode should be off.
OPERATION 201054 - 4500W WIRELESS START OPEN FRAME INVERTER Moving the Generator Manual Stop 1. Turn off and unplug all electrical connected loads. Never start CAUTION or stop the generator with electrical devices plugged in or turned on. – NEVER lift or carry the generator using the folding handle.
MAINTENANCE 201054 - 4500W WIRELESS START OPEN FRAME INVERTER Operation at High Altitude NOTICE The density of air at high altitudes is lower than at sea level. For Emission control devices and systems, read and Engine power is reduced as the air mass and air-fuel ratio understand your responsibilities for service as stated in the decrease.
MAINTENANCE 201054 - 4500W WIRELESS START OPEN FRAME INVERTER 2. Allow the oil to drain completely into an appropriate container. 5. Refer to the spark plug types in Specifications when replacing the plug. 6. Firmly re-install the plug. 7. Attach the spark plug cable to the spark plug.
MAINTENANCE 201054 - 4500W WIRELESS START OPEN FRAME INVERTER Disconnect the Battery 5. Replace the spark arrestor if it is damaged. 6. Position the spark arrestor on the muffler and attach with the 1. Pull two halves of battery connector apart.
STORAGE 201054 - 4500W WIRELESS START OPEN FRAME INVERTER STORAGE 5. Carefully remove the circuit board to locate and replace the CR2016 battery. WARNING 6. Reverse the above instructions to reassemble the remote key fob. To avoid accidental or unintended ignition of your generator...
STORAGE 201054 - 4500W WIRELESS START OPEN FRAME INVERTER 5. When gasoline stops flowing, rotate drain screw clockwise until tight. Properly dispose of the drained gasoline according to local regulations or guidelines. 6. Turn the fuel dial to the “STOP” position.
TROUbLESHOOTING 201054 - 4500W WIRELESS START OPEN FRAME INVERTER TROUbLESHOOTING Problem Cause Solution No fuel. Add fuel. Faulty spark plug. Clean and adjust spark plug or replace. Fill crankcase to the proper level. Low oil level. Place generator on a flat, level surface.
Page 37
TROUbLESHOOTING 201054 - 4500W WIRELESS START OPEN FRAME INVERTER Problem Cause Solution Out of fuel. Fill fuel tank. Fill crankcase to the proper level. Place generator on a Low oil level. flat, level surface. Move generator to an open, outdoor area. Point exhaust away from people and buildings.
Page 38
TROUbLESHOOTING 201054 - 4500W WIRELESS START OPEN FRAME INVERTER Problem Cause Solution Review load and adjust. See “Connecting Electrical Generator is overloaded. Loads.” Generator cannot supply enough Dirty air filter. Clean or replace air filter. power or overheating. Move choke until it stops under RUN position or push in Choke in wrong position.
WARRANTY 201054 - 4500W WIRELESS START OPEN FRAME INVERTER WARRANTY* Other Exclusions This warranty excludes: CHAMPION POWER EQUIPMENT – Cosmetic defects such as paint, decals, etc. 3 YEAR LIMITED WARRANTY – Wear items such as filter elements, o-rings, etc. Warranty Qualifications –...
Page 40
THE UNITED STATES ENVIRONMENTAL PROTECTION AGENCY (U.S. EPA) AND THE CALIFORNIA AIR RESOURCES BOARD (CARB) EMISSION CONTROL SYSTEM WARRANTY Your Champion Power Equipment (CPE) engine complies with both the U.S. EPA and state of California Air Resources Board (CARB) Exhaust and Evaporative emissions regulations.
Page 41
EXHAUST AND EVAPORATIVE EMISSION CONTROL SYSTEM WARRANTY The following are specific provisions relative to your Exhaust and Evaporative Emission Control System (ECS) Warranty Coverage. 1. APPLICABILITY: This warranty shall apply to 1995 and later model year California small off-road engines (SORE) (for other states, 1997 and later model year engines).
Page 42
You must take your CPE engine or the product on which it is installed, along with your warranty registration card or other proof of original purchase date, at your expense, to any Champion Power Equipment dealer who is authorized by Champion Power Equipment, Inc. to sell and service that CPE product during his normal business hours.