CC Series Wiring
A CC series lightbar has a 2-wire power cable and a 16-wire control cable. The entire power load of the bar goes through the power cable.
The black ground wire should be connected directly to the battery. The 10 AWG red power wire requires a constant 10 to 16V power source
with a customer supplied in line fuse. To select an appropriately rated ATO (regular) or Maxi Fuse, add the amp ratings, found in the speci-
fications section, of the modules in your configuration specific lightbar and based on that sum, insert a fuse of the next larger size (to be no
larger than a 30 A fuse). The 16 control cable wires carry only low power (30 mA average) input signals to control the lightbar functions and
must be routed to the output of a control switch (or directly to multiple switches).
Before attempting to connect the lightbar wiring harness, refer to the configuration specific wiring key included with the lightbar for the con-
figuration specific functions of each wire. Use an appropriate high-temperature wiring if it passes through the engine compartment. Use cable
ties and grommets to secure and protect all cables and wires.
Function Wire Color
GRN/BLK
WHT/BLK
RED/BLK
RED
ORG
WHT
BLK/RED
BLK
ORG/BLK
BLU/WHT
BLK/WHT
RED/WHT
GRN/WHT
BLU/BLK
GRN
BLU
Note:
-When the Arrowstik Left and Arrowstik Right wires are both connected to +power, the Center-Out Arrowstik function is activated.
-The Front Cut and Rear Cut functions must be used with the greatest care to ensure that the use of these functions do not diminish
the effectiveness of the Emergency Warning signal.
-When the Pattern Select wire is connected to +power alone, test mode is enabled to exercise all outputs in sequence.
-The Dim Function lowers the brightness of the LEDs in both the ArrowStik mode and Emergency Warning Flash modes.
-The WHT Drivers Side Cut wire may be changed to Arrowstik Flash. Please see the Arrowstik flash pattern selection section below
for details.
-Lightbars equipped with a DOT strip assembly are wired in conjunction with the STT tail light function. All STT functions are
powered independent of the central driver PCA.
Emergency Mode Flash Pattern Selection
There are seven customizable emergency flash pattern modes available based on the wire combinations shown in TABLE 3. When using
individual switches, make sure to configure all possible switch combinations. The default setting is unsynchronized which allows each light
head module group to be configured separately and the lightbar to flash in an unsynchronized pattern. Steps to synchronize the light head
module groups together are detailed in later sections.
Standard CC Function Wire Definitions
Function
L1
Level 1 Emergency Mode
L2
Level 2 Emergency Mode
L3
Level 3 Emergency Mode
Arrowstik Left
Left Arrowstick
Arrowstick Right
Right Arrowstick
Drivers Side Cut
Cut Driver Side Directional and Alley
Lights
Pattern Select
Pattern Select
Take Down Flash
Take Down/Work Light Wig/Wag Flash
Take Down Lights
Take Down/Work Light Steady Burn
Alley Light Flash
Enables Alley Light Wig/Wag Flash
Left Alley Light
Left Alley Steady Burn
Right Alley Light
Right Alley Steady Burn
Front Cut-Off
Blacks-Out Front Facing LEDs
Rear Cut-Off
Blacks-Out Rear Facing LEDs
Cruise Lights
End LEDs only
Lightbar DIM
Sets LEDs to DIM mode
Level Mode Combinations
Function Wire Color
GRN/BLK
WHT/BLK
GRN/BLK & WHT/BLK
RED/BLK
GRN/BLK & RED/BLK
WHT/BLK & RED/BLK
GRN/BLK, WHT/BLK & RED/BLK
Description
TABLE 2
Flash Pattern Modes
L1
L2
L1 + L2
L3
L1 + L3
L2 + L3
L1 + L2 + L3
TABLE 3
Notes
Overrides L1, L2, & L3 for rear of lightbar
Overrides L1, L2, & L3 for rear of lightbar
Designed to interface with the driver's door
switch
Overrides Take Down Flash
Overrides Alley Light Flash
Overrides Alley Light Flash
Overridden by all other functions except for Dim