BLACKMER SMVP50B Installation, Operation And Maintenance Instructions

BLACKMER SMVP50B Installation, Operation And Maintenance Instructions

Blackmer seal-less pumps

Advertisement

Quick Links

BLACKMER SEAL-LESS PUMPS
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS
MODELS:
SMVP50B, SMVP100B, SMVP200B
Discontinued Models: MVP50B, MVP100B, SMVP300B
2007:

TABLE OF CONTENTS

Technical Data....................................................... 2
Initial Pump Start Up Information........................... 2
Pre-Installation Cleaning........................................ 3
Location and Piping ............................................... 3
Check Valves......................................................... 3
Pump Mounting...................................................... 3
Motor Installation ................................................... 4
Pre-Start Up Check List ......................................... 5
Start Up Procedures .............................................. 5
Pump Rotation ....................................................... 5
Reverse Rotation ................................................... 5
Flushing the Pump................................................. 5
Pump Relief Valve ................................................. 6
Relief Valve Setting and Adjustment ..................... 6
Strainers ................................................................ 7
Lubrication ............................................................. 7
Vane Replacement ................................................ 8
Pump Disassembly ................................................ 8
Pump Assembly..................................................... 9
TROUBLE SHOOTING ......................................
NOTE: Numbers in parentheses following individual parts
indicate reference numbers on Blackmer Parts Lists 108-
B01, 108-B02 and 108-B03.
NOTE: Blackmer pump manuals & parts lists may be
obtained from Blackmer's website (www. blackmer. com)
or by contacting Blackmer Customer Service
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the product, or in the
manual, look for one of the following signal words and be
alert to the potential for personal injury, death or major
Warns of hazards that WILL cause serious personal injury,
Page
death or major property damage.
Warns of hazards that CAN cause serious personal injury,
death or major property damage.
Warns of hazards that CAN cause personal injury
Indicates special instructions which are very
important and must be followed.
Blackmer Seal-Less pumps MUST only be installed In
systems, which have been designed by qualified
engineering personnel. The system MUST conform to
all applicable local and national regulations and safety
standards.
This manual is intended to assist in the installation
and operation of the Blackmer Seal-Less pumps, and
MUST be kept with the pump.
11
Blackmer Seal-Less pump service shall be performed
by qualified technicians ONLY. Service shall conform
to all applicable local and national regulations and
safety standards.
Thoroughly review this manual, all instructions and
hazard warnings, BEFORE performing any work on
the Blackmer Seal-Less pumps.
Maintain ALL system and Blackmer Seal-Less pump
operation and hazard warning decals.
960902
INSTRUCTIONS NO. 108-B00_apr05
Section
108
Effective
April 2005
Replaces
July 2002
SAFETY DATA
property damage
or property damage.
NOTICE:
NOTICE:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMVP50B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BLACKMER SMVP50B

  • Page 1: Table Of Contents

    B01, 108-B02 and 108-B03. safety standards. NOTE: Blackmer pump manuals & parts lists may be Thoroughly review this manual, all instructions and obtained from Blackmer’s website (www. blackmer. com) hazard warnings, BEFORE performing any work on or by contacting Blackmer Customer Service the Blackmer Seal-Less pumps.
  • Page 2: Pump Data

    Technical Data is for standard materials of construction. Consult Blackmer Material Specs for optional materials of construction. * Conversion is based on a specific gravity of 1.0. FAILURE TO USE CARE WHEN INITIAL PUMP START UP INFORMATION...
  • Page 3: Installation

    Install vacuum and pressure gauges in the 1/4" NPT SMVP200B/300B models or a foot mounted 254-256TC motor ports provided in the pump cylinder to check pump at frame for SMVP50B/100B and MVP50B/100B models, shims are start up. required under the magnet housing to support the motor frame.
  • Page 4: Motor Installation

    Tighten the 3 bolts in a uniform sequence. Slide the motor adapter ring (86) over the outer magnet On SMVP50B/100B & MVP50B/100B models: torque to to the “C-Face” of the motor. Ensure that the flange of 9 ft lbs. (12.2 Nm) the motor adapter ring is fully and squarely seated.
  • Page 5: Operation

    OPERATION Inspect piping, fittings and associated system equipment for leaks, noise, vibration and overheating. If equipped, check the pressure relief setting of the pump OPERATION WITHOUT COUPLING relief valve by gradually closing a valve in the discharge GUARD CAN CAUSE SERIOUS line momentarily and noting the reading on the pressure PERSONAL INJURY, DEATH OR MAJOR gauge.
  • Page 6: Pump Relief Valve

    (2) outward, or COUNTERCLOCKWISE. Install a new R/V O-ring / gasket (88), and re-attach the R/V cap. Refer to corresponding Blackmer pump parts lists for relief valve spring pressure ranges. Unless specified otherwise, pumps are supplied from the factory with the relief valve adjusted to the mid-point of the spring range.
  • Page 7: Maintenance

    MAINTENANCE FAILURE TO DISCONNECT AND OPERATION WITHOUT GUARDS IN LOCKOUT ELECTRICAL POWER PLACE CAN CAUSE SERIOUS BEFORE ATTEMPTING MAINTENANCE PERSONAL INJURY, MAJOR CAN CAUSE SHOCK, BURNS OR PROPERTY DAMAGE, OR DEATH. DEATH Hazardous voltage. Do not operate Can shock, burn or without guard cause death.
  • Page 8: Vane Replacement

    FORCIBLY PULLING THE PUMP ASSEMBLY INWARD. casing. 4. On SMVP50B/100B & MVP50B/100B models: While 14. RELIEF VALVE DISASSEMBLY (if equipped) facing the outboard end of the pump, grasp the pump a.
  • Page 9: Pump Assembly

    MAINTENANCE MAGNET HOUSING DISASSEMBLY 1. Remove the four housing/adapter capscrews (54B), and pull the motor, motor adapter (86) and outer magnet (53) from the magnet housing (57). 2. Remove the motor adapter capscrews (56), and the motor adapter (86) from the motor. 3.
  • Page 10 TOWARDS the direction of rotation. Refer back to On SMVP50B/100B & MVP50B/100B models: if the inside Figure 3. If necessary, move the push rods with a diameter of the bearing measures 1.196" (30.38mm) or small screwdriver to install the vanes.
  • Page 11: Troubleshooting

    MAINTENANCE OUTER MAGNET ASSEMBLY 6. Using an appropriately sized hoist CAREFULLY slide the Follow instructions given in the MOTOR INSTALLATION pump assembly into the mounted magnet housing. Section of this Manual. On SMVP200B/300B models if motor, adapter ring, and outer magnet are in place, the jackscrews (54C), installed FINAL ASSEMBLY in the magnet housing during disassembly, will hold the When Outer Magnet &...
  • Page 12 Visit www.blackmer.com for complete information on all Blackmer products 1809 Century Avenue, Grand Rapids, Michigan 49503-1530 U.S.A. Telephone: (616) 241-1611 • Fax: (616) 241-3752 E-mail: blackmer@blackmer.com • Internet Address: www .blackmer.com...

This manual is also suitable for:

Smvp100bSmvp200bMvp50bMvp100bSmvp300b

Table of Contents