BLACKMER SMVP15B Installation, Operation And Maintenance Instructions

Seal-less pumps

Advertisement

Quick Links

BLACKMER SEAL-LESS PUMPS
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS
Discontinued Models: SMVP15B, SMVP30B

TABLE OF CONTENTS

Technical Data ....................................................... 2
Initial Pump Start Up Information ........................... 2
Pre-Installation Cleaning ........................................ 3
Location and Piping ............................................... 3
Check Valves ......................................................... 3
Pump Mounting ...................................................... 3
Motor Installation ................................................... 4
Pre-Start Up Check List ......................................... 5
Start Up Procedures .............................................. 5
Pump Rotation ....................................................... 5
Reverse Rotation ................................................... 5
Flushing the Pump ................................................. 5
Pump Relief Valve ................................................. 6
Relief Valve Setting and Adjustment ..................... 6
Strainers ................................................................ 7
Lubrication ............................................................. 7
Vane Replacement ................................................ 8
Pump Disassembly ................................................ 8
Pump Assembly ..................................................... 9
TROUBLE SHOOTING ......................................
NOTE: Numbers in parentheses following individual parts
indicate reference numbers on Blackmer Parts Lists 108-
A02
NOTE: Blackmer pump manuals & parts lists may be
obtained from Blackmer's website (www. blackmer. com)
or by contacting Blackmer Customer Service
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the product, or in the manual,
look for one of the following signal words and be alert to the
potential for personal injury, death or major property damage
Warns of hazards that WILL cause serious personal injury,
death or major property damage.
Warns of hazards that CAN cause serious personal injury,
death or major property damage.
Page
Warns of hazards that CAN cause personal injury
Indicates special instructions which are very
important and must be followed.
Blackmer Seal-Less pumps MUST only be installed In
systems, which have been designed by qualified
engineering personnel. The system MUST conform to
all applicable local and national regulations and
safety standards.
This manual is intended to assist in the installation
and operation of the Blackmer Seal-Less pumps, and
MUST be kept with the pump.
Blackmer Seal-Less pump service shall be performed
by qualified technicians ONLY. Service shall conform
to all applicable local and national regulations and
safety standards.
Thoroughly review this manual, all instructions and
11
hazard warnings, BEFORE performing any work on
the Blackmer Seal-Less pumps.
Maintain ALL system and Blackmer Seal-Less pump
operation and hazard warning decals.
960901
INSTRUCTIONS NO. 108-A00_0704
Section
108
Effective
April 2007
Replaces
April 2005
SAFETY DATA
or property damage.
NOTICE:
NOTICE:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMVP15B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BLACKMER SMVP15B

  • Page 1: Table Of Contents

    Blackmer Parts Lists 108- Maintain ALL system and Blackmer Seal-Less pump operation and hazard warning decals. NOTE: Blackmer pump manuals & parts lists may be obtained from Blackmer’s website (www. blackmer. com) or by contacting Blackmer Customer Service...
  • Page 2: Pump Data

    If replacement parts personal injury are needed, or if information pertaining to the pump is required, this data must be furnished to a Blackmer representative. Strong magnetic field can cause TECHNICAL DATA...
  • Page 3: Installation

    INSTALLATION NOTICE: Check alignment of pipes to pump to avoid strains which Blackmer seal-less pumps must only be installed in might later cause misalignment. See Figure 1. Unbolt systems designed by qualified engineering personnel. flanges or break union joints. Pipes should not spring System design must conform with all applicable away or drop down.
  • Page 4: Motor Installation

    INSTALLATION MOTOR INSTALLATION Strong magnetic field can cause personal injury or death to individuals with medical implants or other magnetic field sensitive medical conditions Strong Magnetic field Failure to use care when handling Figure 3 magnets can cause personal injury Strong magnetic field can cause Dim “A”...
  • Page 5: Operation

    OPERATION If possible, check the flow rate to ensure the pump is operating within expected parameters. Inspect piping, fittings and associated system equipment Operation without coupling guard can for leaks, noise, vibration and overheating. cause serious personal injury, death or If equipped, check the pressure relief setting of the pump major property damage relief valve by gradually closing a valve in the discharge...
  • Page 6: Pump Relief Valve

    Incorrect settings of the pressure relief The SMVP15B and SMVP30B pump models are offered with valve can cause pump component an optional pump relief valve assembly that bolts onto the failure, personal injury and property pump cylinder.
  • Page 7: Maintenance

    MAINTENANCE Failure to disconnect and lockout Operation without guards in place can electrical power before attempting cause serious personal injury, major maintenance can cause shock, burns or property damage, or death. death Hazardous voltage. Do not operate Can shock, burn or without guard cause death.
  • Page 8: Vane Replacement

    MAINTENANCE VANE REPLACEMENT Drain the pump and system, as required. Drain plugs (73A) are located at the base of the cylinder of SMVP Models. Failure to use care when handling For replacement of the vanes ONLY, remove the outboard magnets can cause personal injury head, following steps 10 and 11 in the "Pump Disassembly"...
  • Page 9: Pump Assembly

    MAINTENANCE MAGNET HOUSING DISASSEMBLY 2. Install the disc (71) on the outboard end of the cylinder with Remove the four housing/adapter capscrews (54B), and the disc holes positioned as shown in Figure 5. Use the pull the motor, motor adapter (86) and outer magnet (53) dowel locator pin hole to locate the disc.
  • Page 10 MAINTENANCE RELIEF VALVE ASSEMBLY (If Equipped) Insert the valve (9) into the relief valve bore of the casing with the fluted end inward. Install the relief valve spring (8) and spring guide (7) against the valve. Attach a new relief valve O-ring (10) and the valve cover (4) on the cylinder.
  • Page 11: Troubleshooting

    TROUBLESHOOTING NOTICE: Maintenance shall be performed by qualified technicians only, following the appropriate procedures and warnings as presented in this manual. PROBLEM CAUSE Suction/discharge valve incorrectly set. Pump Not Priming Leaks in suction piping. See causes 1 through 7 Incorrect rotation. Broken shaft.
  • Page 12 Accessories Dispensing, Transfer, In-line Gear Reducers, Bypass Valves, Strainers Visit www.blackmer.com for complete information on all Blackmer products 1809 Century Avenue, Grand Rapids, Michigan 49503-1530 U.S.A. Telephone: (616) 241-1611 • Fax: (616) 241-3752 E-mail: blackmer@blackmer.com • Internet Address: www .blackmer.com...