BLACKMER SX1220A Installation, Operation And Maintenance Instructions

BLACKMER SX1220A Installation, Operation And Maintenance Instructions

Truck pumps

Advertisement

Quick Links

BLACKMER TRUCK PUMPS
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS
Numbers in parentheses following individual parts
indicate reference numbers on Blackmer Parts Lists
104-C02.
Blackmer pump manuals and parts lists may be
obtained from Blackmer's website (www.blackmer.com)
or by contacting Blackmer Customer Service.
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the product, or in the
manual, look for one of the following signal words and be
alert to the potential for personal injury, death or major
property damage
Warns of hazards that WILL cause serious personal injury,
death or major property damage.
Warns of hazards that CAN cause serious personal injury,
death or major property damage.
Warns of hazards that CAN cause personal injury
or property damage.
NOTICE:
Indicates special instructions which are very
important and must be followed.
MODEL: SX1220A
SAFETY DATA

TABLE OF CONTENTS

Technical Data ....................................................... 2
Initial Pump Start Up Information ........................... 2
Pre-Installation Cleaning ........................................ 3
Location and Piping ............................................... 3
Pump Drive ............................................................ 3
Pump Rotation ....................................................... 4
To Change Pump Rotation .................................... 4
Pre-Start Up Check List ......................................... 5
Start Up Procedures .............................................. 5
Pump Speed .......................................................... 5
Reverse Rotation ................................................... 5
Flushing the Pump ................................................. 6
Pump Relief Valve ................................................. 6
Relief Valve Setting and Adjustment ..................... 7
Strainers ................................................................ 7
Lubrication ............................................................. 7
Vane Replacement ................................................ 8
Pump Disassembly ................................................ 8
Pump Assembly ..................................................... 9
TROUBLE SHOOTING .....................................
NOTICE:
Blackmer Truck Pumps MUST only be installed in systems,
which have been designed by qualified engineering
personnel.
The system MUST conform to all applicable
local and national regulations and safety standards.
This manual is intended to assist in the installation and
operation of the Blackmer truck pumps, and MUST be kept
with the pump.
Pump service shall be performed by qualified technicians
ONLY. Service shall conform to all applicable local and
national regulations and safety standards.
Thoroughly review this manual, all instructions and hazard
warnings, BEFORE performing any work on the pump.
Maintain ALL system and pump operation and hazard
warning decals.
961929
INSTRUCTIONS NO. 104-C00
Section
104
Effective
Aug 2023
Replaces
New
Page
11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SX1220A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BLACKMER SX1220A

  • Page 1: Table Of Contents

    This manual is intended to assist in the installation and operation of the Blackmer truck pumps, and MUST be kept with the pump. Warns of hazards that WILL cause serious personal injury, Pump service shall be performed by qualified technicians death or major property damage.
  • Page 2: Pump Data

    A pump Identification tag, containing the pump serial number, I.D. number, and model designation, is attached to each pump. It is recommended that the data from this tag be recorded and filed for future reference. If replacement parts are needed, or if information pertaining to the pump is required, this data must be furnished to a Blackmer representative. TECHNICAL DATA...
  • Page 3: Installation

    INSTALLATION NOTICE: Install pressure gauges in the NPT ports provided in the Blackmer pumps must only be installed in systems pump casing to check pump performance at start up. designed by qualified engineering personnel. System ALL piping and fittings MUST be properly supported to design must conform with all applicable regulations and prevent any piping loads from being placed on the pump.
  • Page 4: Pump Rotation

    INSTALLATION CHECK VALVES The use of check valves or foot valves in the supply tank is not recommended with self-priming, positive displacement pumps. If the possibility of liquid backflow exists when the pump is off, a check valve in the pump discharge piping is recommended because the pump can motor in the reverse rotation and create undue stress on all attached components.
  • Page 5: Operation

    INSTALLATION Operation without guards in place can cause serious personal injury, major property damage, or death. Do not operate without guard in place PUMP ROTATION NOTICE: Confirm correct pump rotation by checking the pump rotation arrows respective to piping flow direction. Do not operate the pump in reverse rotation to reverse the direction of flow.
  • Page 6: Start Up Procedures

    OPERATION START UP PROCEDURES NOTICE: Consult the "General Pump Troubleshooting" section of this manual if difficulties during start up are experienced. Start the pump. Priming should occur within one minute. Check the vacuum and pressure gauges to ensure the pump is operating within the expected conditions. Inspect piping, fittings, and associated system equipment for leaks, noise, vibration and overheating.
  • Page 7: Relief Valve Setting And Adjustment

    DO NOT adjust the relief valve pressure setting while the pump is in operation. Refer to Blackmer Pump Parts List 101-A01 for relief valve spring pressure ranges. Unless specified otherwise, pumps are supplied from the factory with the relief valve adjusted to the mid-point of the spring range.
  • Page 8: Vane Replacement

    MAINTENANCE Bend up the engaged lockwasher tang and rotate VANE REPLACEMENT the locknut counterclockwise to remove it from the NOTICE: shaft. Maintenance shall be performed by qualified technicians Slide the lockwasher off the shaft. Inspect the only. Following the appropriate procedures and lockwasher for damage and replace as required.
  • Page 9: Pump Assembly

    MAINTENANCE PUMP ASSEMBLY 17. Tighten the locknut (24A) with a spanner wrench to pull the rotor flat against the back wall of the cylinder. DO Before reassembling the pump, inspect all component parts NOT overtighten the locknut and bend or shear the inner for wear or damage, and replace as required.
  • Page 10 MAINTENANCE 31. Install and finger tighten the head capscrews (21). The 44. To check adjustment, grasp the nut and washer with head capscrews will be fully tightened after the second fingers and rotate back and forth. If this cannot be done, locknut is installed.
  • Page 11 PUMP TROUBLESHOOTING NOTICE: MAINTENANCE SHALL BE PERFORMED BY QUALIFIED TECHNICIANS ONLY, FOLLOWING THE APPROPRIATE PROCEDURES AND WARNINGS AS PRESENTED IN THIS MANUAL. SYMPTOM PROBABLE CAUSE Pump Not Priming 1. Pump not wetted. 2. Worn vanes. 3. Internal control valve closed. 4.
  • Page 12 NOTES 104-C00 Page 12/14...
  • Page 13 1809 Century Avenue, Grand Rapids, Michigan 49503-1530 U.S.A. Telephone: (616) 241-1611 • Fax: (616) 241-3752 E-mail: blackmer @blackmer.com • Internet Address: www .blackmer.com 104-C00 Page 13/14...
  • Page 14 104-C00 Page 14/14...

Table of Contents