Siemens SIMATIC NET RUGGEDCOM RS910W Installation Manual page 51

Rugged ethernet switches
Table of Contents

Advertisement

Certification
6.2 EMC and Environmental Type Tests
Dielectric Strength
Environmental Type Tests
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2
42
Description
Test
Cold Temperature
Dry Heat
Humidity (Damp
Heat, Cyclic)
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Description
Test Ad
Test Bd
Test Db
Vibration
Shock
Test Levels
5 kV
5 kV
2 kV (Failsafe Relay)
1.5 kV
2 kV
Test Levels
Severity Levels
-40 °C (-40
°F), 16 Hours
85 °C (185
°F), 16 Hours
95% (Non-
Condensing),
55 °C (131
°F), 6 Cycles
2 g @ 10 to 150 Hz
30 g @ 11 ms
Installation Manual, 04/2021, C79000-G8976-1031-12
 
 
 
Class 2
Class 2
RUGGEDCOM RS910W