1.1 Receiving and Inspection

This VFD-L-I AC motor drive has gone through rigorous quality control tests at the factory before
shipment. After receiving the AC motor drive, please check for the following:
Inspect the unit to assure it was not damaged during shipment.
Make sure that the part number indicated on the nameplate corresponds with the part
number of your order.
There is no built-in digital keypad in the VFD-L-I series. It needs to use optional digital
keypad VFD-PU06 or communication method to modify the parameters.

1.1.1 Nameplate Information

Example for 0.25HP 230V AC motor drive
Ou tput Freque nc y Ra nge
Se ria l Number & Bar Co de

1.1.2 Model Explanation

VF D
Seri es Name
Revision July 2009, SW V1.1
Mode l Name
In put Spec.
Ou tput Sp ec .
B
I
007
L
21
Specific for wir e-drawing machi nes
Vers ion T ype
21:Single phase 230V
VF D- L Ser ies
Applicable motor capacity
002: 0.25HP( 0.2kW )

Chapter 1 Introduction

MO DEL : V FD00 2L 21 B- I
INP UT
: 1P H 4.9 A 2 00 -2 40 V 5 0/ 60 Hz
O UTPUT : 3 PH 0 -2 40 V 1 .6A 0.6 kVA 0.2 5HP
Fr eq ue ncy Ra ng e : 0 .1- 40 0Hz
0 02 L2 1B IT70 10 00 1
DELTA ELECTRONI CS I NC.
Input Voltage
MADE I N XXXXX