Modification of this unit in any way will void all warranties and could create safety hazards. Your new Powr-Flite unit is a high quality, precision-made product. All parts used in the manufacturing of this unit have passed rigid quality control standards prior to assembly. Please safeguard the original receipt/invoice given at the time of purchase.
GROUNDING INSTRUCTIONS DANGER: Improper use of the grounding plug can result in a risk of electric shock. WARNING! Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded.
IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE USING THIS UNIT Read and understand this owner’s manual and all labels on the unit before operating. Safety is a combination of common sense,staying alert, and knowing how your unit works. Use this unit only as described in this manual.
General Instructions for the PE310 Series Follow these easy step by step instructions to ensure proper operating performance. 1. If you are not pre-spraying the chemical on the carpet, fill up the fresh water solution tank with tap water that is 120 -135 F (49 C) and approved carpet cleaning chemical following the...
Fig. 1 Fig. 2 Fig. 3 Maintenance To receive reliable service from this equipment, regular daily maintenance is a requirement. Fabric cleaning, both carpet and upholstery, are very dirty environments for any equipment. The following recommendations are offered. 1. Keep the equipment clean, both inside and out. 2.
Fig. 4 Storage of Equipment 1. Store extractor indoors in a dry area. 2. Recovery and solution tank should be empty and clean when the extractor is not in use. 3. Leave the recovery lid and drain hose open to air out the recovery tank. 4.
Troubleshooting Information ELECTRICAL SYSTEM PROBLEM POSSIBLE CAUSE SOLUTION No electrical power. 1. Defective power cord. 1. Replace 2. Circuit breaker off or fuse 2. Turn circuit breaker on or blown. replace fuse. Unplug any equipment using the same circuit. Switch is turned on. 1.
Page 10
PUMP SYSTEM PROBLEM POSSIBLE CAUSE SOLUTION Pump motor runs but no spray 1. Clogged or faulty solution 1. Check intake on valve and through jets. control valve. remove lint or other foreign material. 2. Clogged or faulty quick 2. Depress plunger on solution disconnect on housing.