Fig 3-3 Remote Sense Connection On Front Panel(When Current ≦60A); Fig 3-4 Remote Sense Connection On Rear Panel(When Current >60A) - Prodigit 33501 Series Operation Manual

High power electronic load
Table of Contents

Advertisement

33501 Series Operation Manual 3-11
Fig 3-3 Remote sense connection on front panel(when current ≦60A)
Fig 3-4 Remote sense connection on rear panel(When current >60A)
3.1.24 I-monitor
The I-monitor analog signal is proportional to the load current flow through the
electronic load module.
This is virtual isolated to the Load input, it provides the load current waveform
output to an oscilloscope to evaluate the voltage and current waveform of a power
supply under test.
Note : Don 't use Imonitor with different channel to avoid common ground problem.
Please refer chapter 1, Table 1-1 for voltage /current relationship of each 33501
series module.

Advertisement

Table of Contents
loading

This manual is also suitable for:

335013351133521335313354133512 ... Show all

Table of Contents