Conversion To Natural Gas Or Lpg - CDA HCG 731 Series Installation & Use Manual

Cda - kitchen appliance manufacturer cooktop user manual
Table of Contents

Advertisement

Conversion to Natural Gas or LPG

Replacing the Burner Injectors
If the NATURAL GAS/LPG conversion kit is not supplied with the appliance this kit can be purchased by
contacting the After-Sales Service.
Choose the injectors to be replaced according to the table below.
The injector diameter, expressed in hundredths of a millimetre, is marked on the injector body.
To replace the injectors proceed as follows:
– Remove the pan supports, the burner caps and flame speaders.
– Using a wrench, substitute the nozzle injectors "J" (Figs. 19 - 20) with those most suitable for the kind
of gas for which it is to be used.
The burners are made in such a way so as not to require regulation of the primary air.
Auxiliary,
Semi-Rapid
and Rapid
burners
Fig. 19
Table for the Choice of the Injectors
Burners
Auxiliary (A)
Semi-Rapid (SR)
Rapid (R)
Triple Ring (TR)
Nominal
Reduced
Power
Power
kW
kW
1,00
0,30
1,75
0,45
3,00
0,75
3,50
1,50
Triple Ring
burner
J
Fig. 20
G30 - 28-30 mbar
G31 - 37 mbar
Ø Injector
1/100 mm
50
65
85
95
J
Cat: II 2H 3+
G20 - 20 mbar
Ø Injector
1/100 mm
72 (X)
97 (Z)
115 (Y)
135 (T)
19