It is dangerous to alter the specifications or attempt to modify this product in any way.
Technical Information
DIMENSIONS
ELECTRICAL SUPPLY:
POWER CONSUMPTION:
FAN MOTOR:
LAMP:
SUITABLE FOR INSTALLATION
ABOVE:
This appliance must be earthed

Electrical Requirements

Any permanent electrical installation must comply with
the latest I.E.E. Regulations and local Electricity Board
regulations. For your own safety this should be undertaken
by a qualified electrician e.g. your local Electricity Board,
or a contractor who is on the roll of the National Inspection
Council for Electrical Installation Contracting (NICEIC).

Electrical Connection

Before connecting to the mains supply ensure that the
mains voltage corresponds to the voltage on the rating
plate inside the cooker hood.
Remove the grease filters (see paragraph Maintenance)
being sure that the connector of the feeding cable is
correctly inserted in the socket placed on the side of
the fan.

INSTALLATION INSTRUCTIONS

HEIGHT (CANOPY):
HEIGHT (CHIMNEY):
WIDTH (CANOPY):
WIDTH (CHIMNEY):
GROSS:
NET:
(2x20W) HALOGEN Ø 35 mm GUA
ELECTRIC HOB:
GAS HOB:
SLOT-IN GAS COOKER
SLOT-IN ELECTRIC COOKER
Note: CE Marking certifies that this appliance complies with the requirements laid
down in EEC directive 89:336. (Electromagnetic compatibility) and subsequent
modifications and Low Voltage directive 72/23/E.
ELECTRICAL CONNECTIONS
This appliance is fitted with a 3 core mains cable and
must be permanently connected to the electricity supply
via a double-pole switch having 3mm minimum contact
gap on each pole. A Switched Fuse Connection Unit to
BS1363 Part 4, fitted with a 3 Amp fuse, is a recommended
mains supply connection accessory to ensure compliance
with the Safety Requirements applicable to fixed wiring
instructions.
This appliance conforms to BS 800: 1988 and EEC
Directive No. 78 308 regarding suppression of radio and
television interference.
12
760 mm
300-300 mm
898 mm
300 mm
47 kg
37,4 kg
220-240 V (50 Hz)
370 W
330 W
40 W
7 KW
10 KW
13.5 KW
12.4 KW