Input Circuits

Start, Reset, and Gate Input
H5CL-A
IN

Input Connections

Open Collector Output
PC or sensor
AC models
DC models
Start, Reset, and Gate Input Specification
ON impedance:
ON residual voltage:
OFF impedance:
Maximum applicable voltage: 30 VDC max.
Two-wire Sensor
Applicable Two-wire Sensor
Leakage current:
Switching capacity: 5 mA min.
Residual voltage:
Operating voltage: 10 VDC
Note: When connecting a two-wire sensor to a DC models, sup-
ply 24 VDC (21.6 to 26.4 VDC) to the timer.
Downloaded from
Elcodis.com
electronic components distributor
(AC Models)
+12 V
1 kΩ
Internal circuit
0 V
Output
12 VDC
3
5
6
7
1
6
8
9
7
500 Ω max. (the leakage current is 5 to 20 mA when the impedance is 0 Ω.)
2 V max.
100 kΩ min.
Sensor
0 V
3
5
6
7
AC models
DC models
6
8
9
7
1.5 mA max.
3 V max.
H5CL-AD
(DC Models)
V
– 3.5V
in
(16V max.)
1 kΩ
IN
Internal circuit
V
: Supply voltage
in
Voltage Output
PC or sensor
0 V
Output
12 VDC
3
5
6
AC models
DC models
6
8
9
Key Protection Input
Key Protection Input
ON impedance:
(the leakage current is approx. 1 mA when the impedance is 0 Ω.)
ON residual voltage:
OFF impedance:
Maximum applicable voltage: 30 VDC max.
Note: The used contact should switch 1 mA at 5 V.
Key Protection Input
+5 V
4.7 kΩ
IN
Note:
No key input is effective while
key protection input is ON.
Contact input
7
1
AC models
3
7
DC models
6
Open collector
or
contact
3
4
AC models
DC models
6
10
1 kΩ max.
0.5 V max.