Toshiba TOSDIC-CIE DS Instruction Manual
Toshiba TOSDIC-CIE DS Instruction Manual

Toshiba TOSDIC-CIE DS Instruction Manual

Historical data auto save package
Hide thumbs Also See for TOSDIC-CIE DS:

Advertisement

Quick Links

Toshiba Integrated Control System
Historical data Auto Save Package
Instruction Manual
6F8C1046

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba TOSDIC-CIE DS

  • Page 1 Toshiba Integrated Control System Historical data Auto Save Package Instruction Manual 6F8C1046...
  • Page 2 Edition 25 May, 2018 The contents of this manual may be revised without notice.  Copy right 2018 TOSHIBA INFRASTRUCTURE SYSTEMS & SOLUTIONS Corporation. All rights reserved. No part of this manual may be reproduced in any form without permission.
  • Page 3 Introduction Safety Precautions The instruction manual and the labels affixed to the products or equipment give important information for using products safely. It helps prevent damage to properties and hazard to people who use them or work with them. Make yourself familiar with the signal words and signs in this page, then read the safety precautions that follow and always follow the instructions to avoid hazards.
  • Page 4 Introduction Caution While FDD lamp on the floppy disk drive is lit, data is being  recorded or read. • If the following are executed during this period, the content of the Operation prohibited while floppy disk may be destroyed: FDD lamp lights •...
  • Page 5 • To use this product in a system where equipment such as the one human safety is involved and affecting the maintenance of public function(Note 2), special consideration (Note 3) regarding the system’s operation, maintenance and control is required. Contact Toshiba’s sales department. Note 1 Example of equipment directly involved in human life is as follows: •...
  • Page 6 • Toshiba is not liable for any incidental damage from use or non use of this product (loss of business profit, discontinuation of business, change or loss of the memorized content and so on).
  • Page 7: Introduction

    Introduction Introduction Toshiba's next-generation CIE integrated control system TOSDIC-CIE DS is an integrated production system merging a de-facto standard and Toshiba's unique control technology. The advanced control and computer technologies of Toshiba combine a standard multi-vendor network and integrated engineering tool which is easy to use, to implement a high-reliability system in an open environment..
  • Page 8 Introduction  Conventions used in this manual Other than safety precaution items, the following symbols are used to explain items that need your attention. Explains items required to use the product correctly. Important: Introduces referential matters to help you understand the main text. Tip: Documents you should refer to help you understand the main text.
  • Page 9: Table Of Contents

    Contents Contents Safety Precautions Introduction 1. Overview of theHistorical data Auto Save Package Functions Basic specifications File composition Operating Conditions Configurations Software configuration Contents of package 2. Install 3. Description of the Screen Historical Data Auto Save Screen Error Message...
  • Page 10 Contents...
  • Page 11: Overview Of Thehistorical Data Auto Save Package

    1. Overview of the Advanced Hardcopy Package 1. Overview of the Historical data Auto Save Package Functions The historical data auto save package is a software package that adds the function to save historical data automatically with a specified cycle to OIS-DS. By this function, the printer output of messages is omitted and long-term preservation of data is enabled.
  • Page 12: File Composition

    1. Overview of the Advanced Hardcopy Package File composition The file composition of the saving data is shown in Figure 1.1. Under the specified drive, a "year - month” folder is created and data is saved. ex.) It is as follows when "removable disk (D) “ - “D:\OISHM.CSV" is specified. "removable disk (D) “...
  • Page 13: Configurations

    1. Overview of the Advanced Hardcopy Package Configurations Software configuration The historical data auto save package has the following software. Uses detail setup parameters to convert colors black and white to print them. Package CD : HM Data Auto Save Type : ECPHAHDA Contents of package...
  • Page 14: Install

    2. Install 2. Install The package of the historical data auto save is installed in accordance with the following procedure. INSTRUCTION: Before performing installation/uninstallation, check to make sure that the OIS window is not started. 1) Click on the <Next> button. Figure 2.1 Historical Data Auto Save Package Setup Dialog Box 2) The execution type selection dialog box is displayed.
  • Page 15 2. Install 3) Select "Install" for the execution type and then click on the <Next> button. The installation destination selection dialog box is displayed. Figure 2.3 Installation Destination Selection Dialog Box 4) Specify the installation destination (default: C:\OIS\) and then click on the <Next> button. The program folder selection dialog box is displayed.
  • Page 16 2. Install 5) Specify the program folder (default: OIS-DS Program) and then click on the <Next> button. The installation is executed and the completion message is displayed. Figure 2.5 Completion Message 6) Click on the <OK> button. Thus, the installation is completed.
  • Page 17: Description Of The Screen

    3. Description of the Screen 3. Description of the Screen Historical Data Auto Save Screen Selecting the [Start up]-[Program]-[OIS-DS program] - [Histrical data AutoSave] menu displays the following dialog box. Figure 3.1 Historical Data Auto Save Dialog Box Screen display 1) Setting Information Here, set the following data for automatic saving.
  • Page 18 3. Description of the Screen • Saving Folder Input Folder wheredata is saved. (Max 256 bytes, Default folder: “Current drive:\OISHM.CSV”) Or displays Select folder dialog box (Figure 3.2) by pushing <Ref> button. [Folder list] By clicking double or press Enter key on selected item, update the contents of the folder list.
  • Page 19 3. Description of the Screen 3) Saving information Here, displays the automatic saving information. When the screen closes, this information(Pre. saving time / The latest state) is saved in the file. And when the screen starts, it is used. • Pre. saving time Displays the time when the previous saving finished normally.
  • Page 20 3. Description of the Screen Figure 3.3 The Historical Data Auto Save Dialog Box (Saving finished) Buttons 4) <Ref> button Clicking this button displays the Select folder dialog box (Figure 3.2). 5) <Start> button Clicking this button starts automatic saving.By checking the previous saving state when the screen starts, if “Pre.
  • Page 21: Error Message

    3. Description of the Screen Error Message When error occurs at the time of automatic saving execution, an error message is displayed Figure 3.4 Error Message Dialog Box The causes of errors and its messages are shown below. • Failed to read the historical data In ( ) , the detailed error is shown.
  • Page 22 3. Description of the Screen • The availabilities of a saving place drive are insufficient. REFERENCE: About an availability, it calculates with 200 bytes/item before saving. • Media is write-protected. • Media is wrong format. Buttons 4) <Retry> button Clicking this button starts saving again. 5) <Cancel>...
  • Page 24 Industrial Systems Division 72-34, Horikawa-Cho, Saiwai-Ku, Kawasaki 212-8585, Japan...