Installing the Solar-Divicon
The Solar-Divicon and the solar pump assembly are
■
unsuitable for direct contact with swimming pool
water.
■
Every time the system is drained, flush the system
with heat transfer medium.
A tee is available for the purpose of connecting the
■
expansion vessel and the stagnation heat sink in the
flow.
■
Install a thermal insulation loop if the expansion ves-
sel is installed higher than the Solar-Divicon.
Use only bronze, brass or stainless steel fittings,
■
copper or stainless steel pipes or Viessmann stain-
less steel solar circuit pipes for the installation.
Use hemp only in conjunction with pressure and tem-
perature-resistant sealants.
Check the sealing faces for cleanliness and damage
■
before assembly.
The discharge pipe must exit into an open container.
■
Installation sequence
11