Download Print this page

Viessmann Solar-Divicon PS10 Installation And Service Instructions Manual page 17

Hide thumbs Also See for Solar-Divicon PS10:

Advertisement

Replacing the circulation pump
HE circulation pump with PWM control, types PS20 and P20
800
80
600
60
400
40
200
20
0
0
0
Pump rate in m³/h
0
Pump rate in l/min
Fig. 12
Pressure drop curve
A
Max. delivery head
B
LED on the HE circulation pump
LED
Illuminates green.
Flashes green in short in-
tervals.
Fault indications
Flashes red and green
alternately
Flashes red
LED off
(cont.)
0.5
1.0
8.3
16.7
Meaning
Circulation pump in opera-
tion
Circulation pump in stand-
by
Circulation pump is ready
for operation but not run-
ning.
Note
The circulation pump
starts automatically after
the cause of the fault has
been removed.
Circulation pump switched
off (blocked)
B
A
1.5
2.0
25
33.2
Cause
Undervoltage (< 160 V~)
Overvoltage (> 253 V~)
Motor temperature too
high
Circulation pump does not
start automatically.
No power.
LED faulty
PCB faulty
Installation sequence
2.5
41.7
Remedy
Check the power supply.
(195 V~ < U < 253 V~)
Check ambient and heat
transfer medium tempera-
tures.
Replace circulation pump
(see page 15)
Check connecting cable.
Check whether the circula-
tion pump is running.
Replace the circulation
pump (see page 15).
17

Advertisement

loading