Oriental motor AR Series Operating Manual
Oriental motor AR Series Operating Manual

Oriental motor AR Series Operating Manual

Hide thumbs Also See for AR Series:

Advertisement

Quick Links

O P E R AT I N G M A N U A L
Stepping motor
AR Series FR geared type
Motor Edition
Introduction .............................................. 1
Safety precautions .................................. 1
Precautions for use ................................. 2
Preparation ................................................ 3
Installation ................................................. 4
Connection ................................................ 6

Introduction

„ Before use
Only qualified personnel of electrical and mechanical engineering should
work with the product.
Use the product correctly after thoroughly reading the section "Safety
precautions. " In addition, be sure to observe the contents described in
warning, caution, and note in this manual.
The product described in this manual is designed and manufactured to
be incorporated in general industrial equipment. Do not use for any other
purpose. Oriental Motor Co., Ltd. is not responsible for any compensation for
damage caused through failure to observe this warning.
„ Related operating manuals
For operating manuals not included with the product, contact your nearest
Oriental Motor sales office or download from Oriental Motor Website
Download Page.
Operating manual name
AR Series FR geared type OPERATING MANUAL
Motor Edition (this document)
AR Series/Motorized Actuator equipped with AR Series
USER MANUAL
APPENDIX UL Standards for AR Series

Safety precautions

The precautions described below are intended to ensure the safe and correct
use of the product, and to prevent the customer and others from exposure
to the risk of injury. Use the product only after carefully reading and fully
understanding these instructions.
Description of signs
Handling the product without observing the instructions
that accompany a
serious injury or death.
Handling the product without observing the instructions
that accompany a
or property damage.
The items under this heading contain important handling
instructions that the user should observe to ensure the
safe use of the product.
The items under this heading contain related information
and contents to gain a further understanding of the text
in this manual.
HM-60414
Specifications ............................................ 6
General specifications ........................... 7
Regulations and standards .................. 7
Cables .......................................................... 7
Included or not
included with product
Included
Not included
Included
"
"
WARNING
symbol may result in
"
CAUTION
"
symbol may result in injury
Thank you for purchasing an Oriental Motor product.
This Operating Manual describes product handling procedures and safety
precautions.
y Please read it thoroughly to ensure safe operation.
y Always keep the manual where it is readily available.
General
y Do not use the motor in explosive or corrosive environments, in the
presence of flammable gases, in places subjected to splashing water, or
near combustibles. Doing so may result in fire, electric shock, or injury.
y Assign qualified personnel to the task of installing, wiring, operating/
controlling, inspecting, and troubleshooting the motor. Handling by
unqualified personnel may result in fire, electric shock, injury, or damage to
equipment.
y Do not transport, install, connect, or inspect the motor while the power is
supplied. Always turn the power off before carrying out these operations.
This may result in electric shock.
y Take measures to keep the moving part in position if the motor is used
in vertical operations such as elevating equipment. The motor loses the
holding torque when the power is shut off, allowing the moving parts to fall
and possibly cause injury or damage to equipment.
y The brake mechanism of the electromagnetic brake motor is used for the
purpose to hold the moving part and motor in position. Do not use the
brake mechanism of the electromagnetic brake motor for braking or as a
safety brake. Doing so may result in injury or damage to equipment.
Installation
y When installing the motor, prevent from directly touching the motor, or
make sure to ground it. Failure to do so may result in electric shock.
Connection
y Connect the motor securely according to the motor connection method
explained in the USER MANUAL. Failure to do so may result in fire or electric
shock.
y Do not forcibly bend, pull, or pinch the connection cable. Doing so may
result in fire or electric shock.
Repair, disassembly, and modification
y Do not disassemble or modify the motor. Doing so may result in electric
shock or injury. Refer all such internal inspections and repairs to the Oriental
Motor sales office from which you purchased the product.
General
y Do not use the motor beyond its specifications. Doing so may result in
electric shock, injury, or damage to equipment.
y Do not touch the motor during operation or immediately after stopping.
The surface is hot, and this may cause a skin burn(s).
Transportation
y Do not carry the motor by holding the motor output shaft, the load shaft,
or the cable. Doing so may result in injury.
Installation
y Install the safety cover on the output shaft. Failure to do so may result in
injury.
y Do not leave anything around the motor that would obstruct ventilation.
Doing so may result in damage to equipment.
1

Advertisement

Table of Contents
loading

Summary of Contents for Oriental motor AR Series

  • Page 1: Table Of Contents

    Do not use for any other safety brake. Doing so may result in injury or damage to equipment. purpose. Oriental Motor Co., Ltd. is not responsible for any compensation for damage caused through failure to observe this warning.
  • Page 2: Precautions For Use

    • Noise elimination measures Operation Refer to the USER MANUAL for the noise elimination measures. y Do not touch the motor output shaft or the load shaft during operation. Doing so may result in injury. • Peak torque y Provide an emergency stop device or emergency stop circuit external to Always operate the motor under a load not exceeding the peak torque.
  • Page 3: Preparation

    The figure shows an electromagnetic brake motor which cable outlet direction is rightward. Verify that the items listed below are included. Report any missing or damaged items to the Oriental Motor sales office from which you purchased • Front face the product.
  • Page 4: Installation

    z Using the rear face as the mounting surface Installation When installing using the rear face, the center axes of the motor and the metal plate cannot be aligned due to no pilot. „ Installation location If the centering is needed, adjust the center axes by yourself. The motor is designed and manufactured to be incorporated in equipment.
  • Page 5 z When the non-stepped load shaft is installed z When the stepped load shaft is installed First, put a retaining ring for hole. Then, use spacers, a plain washer, and a • Installation using end plate spring washer to secure the load shaft with a screw. Also, put the spacer to the load shaft side.
  • Page 6: Inspection And Maintenance

    Permissible axial Gear ratio „ Warranty mounting surface load [N (lb.)] 10 mm (0.39 in.) 20 mm (0.79 in.) Check on the Oriental Motor Website or General Catalog for the product 900 (200) 770 (173) warranty. 1,300 (290) 1,110 (240) 500 (112) „...
  • Page 7: General Specifications

    Extension cable set model name „ UL Standards Length For electromagnetic For standard type [m (ft.)] brake type Check the APPENDIX UL Standards for AR Series for recognition information 1 (3.3) CC010VAFT2 CC010VAFBT2 about UL Standards. 2 (6.6) CC020VAFT2 CC020VAFBT2 „...
  • Page 8 Unauthorized reproduction or copying of all or part of this manual is prohibited. y Oriental Motor shall not be liable whatsoever for any problems relating to industrial property rights arising from use of any information, circuit, equipment or device provided or referenced in this manual.

This manual is also suitable for:

Arm98ak-fr10

Table of Contents