REQUIRED MAINTENANCE

INSPECTION
Verify operation of the solenoid and auto float drain system.
Verify refrigeration analyzer gauge is in the correct range.
Verify operation of both cooling fans.
General Maintenance
Clean refrigeration condenser coil by blowing dust and dirt from the inside of the cabinet
out. (Opposite from normal fan air flow) Be sure to clean condenser fan motor to provide
adequate cooling and fan blades to allow proper balance.
Isolate the valve prior to the Solenoid drain system and remove and clean the strainer
screen
Replace filter element of inline filters.
Drain Service
If the drain system is not discharging condensate and the strainer is clean, try cleaning
debris from diaphragm, or replacing the solenoid or timer.
If the drain system is continually discharging condensate and air from the drain tube, try
replacing the solenoid valve diaphragm, or the complete drain valve.
Inlet Temp.
Ambient Temp.
70
1.10
80
1.23
90
1.35
100
1.48
110
1.61
120
1.73
130
1.86
140
1.98
150
2.11
To obtain flow capacities at conditions other that standard (SCFM @ 100 PSIG, 100°F Inlet & 100°F
Ambient), locate the multiplier at the interception of actual operating conditions. Multiply the rated capacity
of the selected dryer by the selected multiplier. The result is the corrected flow capacity. Flow rates in
excess of specified due to capacity correction can result in increasing pressure drop.
Disconnect and lockout dryer power as well as compressed air supply and
depressurize prior to performing the following maintenance items.
MODEL CAPACITY CORRECTION MULTIPLIER
90°F
90
100
110
90
1.01
0.86
0.81
1.13
0.96
0.90
1.24
1.06
1.00
1.36
1.15
1.09
1.47
1.25
1.18
1.59
1.35
1.29
1.70
1.45
1.37
1.82
1.55
1.46
1.93
1.64
1.55
GSRN10-2250A-SM
Page 7 of 10
100°F
110°F
100
110
90
100
0.74
0.63
0.60
0.55
0.83
0.70
0.67
0.62
0.91
0.78
0.74
0.68
1.00
0.85
0.81
0.75
1.09
0.92
0.88
0.81
1.17
0.99
0.95
0.87
1.26
1.07
1.02
0.94
1.34
1.14
1.09
1.00
1.42
1.21
1.16
1.06
Frequency
Weekly or
as required.
Frequency
Monthly
Monthly
6 Months or
High differential
Frequency
As Required
As Required
120°F
110
90
100
110
0.47
0.45
0.42
0.35
0.52
0.51
0.47
0.40
0.58
0.56
0.51
0.44
0.63
0.61
0.56
0.48
0.69
0.66
0.61
0.52
0.74
0.72
0.66
0.56
0.80
0.77
0.71
0.60
0.85
0.82
0.75
0.64
0.90
0.87
0.80
0.68