CONDENSATE DRAINS
The condensate system is at line pressure and can cause personal injury or equipment
damage when discharging. Securely anchor the drain pipes or tubes prior to dryer
operation.
Prior to any maintenance isolate and depressurize condensate drain valves.
Internal Float Drain
GSRN-10 through GSRN-40
When maintaining float drains
depressurize the dryer & drain prior
to work initiation.
Drain line and "Drain Connector"
must be removed prior to bowl and
float drain removal.
Condensate discharged from the dryer may contain oil/lubricants.
Verify and follow local regulations regarding disposal.
GSRN10-2250A-SM
Page 5 of 10
Electronic Drain Assembly
GSRN-50 through GSRN-2250
Drain Timer Factory Preset
4 seconds
10 minutes
The factory setting is applicable for virtually all
industrial applications. If adjustment is required
contact your local distributor for alternate settings
and procedures.
on time
off time