FAULTS
Attention!
Before carrying out any work on the device, the mains power supply must be disconnected on all poles and meas-
ures taken to ensure it cannot be inadvertently reconnected.
Warning!
Improper working procedures on live components can cause an electric shock!
Death or serious injury from electric shock!
Work on live components must only be carried out by a qualified electrician.
Warning!
Surface of the submersible pump can be hot!
Minor or severe injuries due to heat!
Wear gloves and touch the submersible pump cautiously.
Fault
Pump does not pump in automatic mode
/ during peak load operation (high water);
no fault is displayed.
"Fault" indicator
"High water" indicator
Water level in the collecting
chamber too high
Note!
In the case of a mains-independent high water alarm, the alarm buzzer can be muted by pressing the "acknowledge" button.
DISMANTLING/DISPOSAL
B 55002.11-2022.01
EASYLOGO 2-00 E
Cause
On-site fuse / FI switch tripped or faulty
The motor protection of the pump has
been triggered
Float switch of one or both pumps
blocked
Insufficient current consumption, or
none at all, by one or both pumps
Pump delivery too low
Inflow too high
On-site fuse/FI switch tripped or faulty
Mains voltage has failed
Action
Check on-site fuse / FI switch
Inform JUNG PUMPEN customer service in the
event of repeated tripping.
Check whether the pump housing has heated up
Let the pump cool down
Check float switch
Unblock float switch till it moves freely
The power consumption of the connected pump
must be at least 320W.
Plug the pump directly into a power socket to
test the switching function.
Clean collecting chamber and pumps
Reduce inflow if possible
Check on-site fuse/FI switch
Inform JUNG PUMPEN customer service in the
event of repeated tripping.
When disposing of the device, relevant national disposal
regulations must be observed.
ENGLISH