6.4
BLK360 power supply
and consumption
GKL312 charging sta-
tion
GEB212 internal bat-
tery
Battery operating and
charging times
6.5
6.5.1
Environmental spe-
cifications BLK360
Technical Data
Scan size for 3 settings:
Resolution
[mm @ 10m]
Fast
Standard
High density

Electrical Data

Power supply:
Internal battery
7.4V DC; one internal battery provided with system.
Power consumption:
Instrument
10 W typical; 16 W max.
Supply
Input voltage
Supply
Type
Voltage
Capacity
Internal battery
Operating time
Charging time

Environmental Specifications

BLK360

Temperature range:
Type
Operating temperature
[°C]
Instrument
+5 to +40
Protection against water, dust and sand:
Type
Protection
Instrument
IP54 (IEC 60529), upright, battery door closed
Dust protected
Protection against splashing water from any direction
Approx. scan size [mio points]
3
18
65
Value
10-32 V DC
Value
Li-Ion
7.4 V
2.6 Ah
Value
> 40 setups per battery, typical continu-
ous use (room temperature).
Typical charging time with charger
GKL312 is 4-8 hours at room temperat-
ure.
Storage temperature
[°C]
-25 to +70