STATOR INSPECTION

Remove the inverter unit.
Pull the recoil starter and measure the voltage between the terminals of the
generator 3P connectors (
• After generator voltage inspection, reset the error log.
Generator
Master
Slave
If the output voltage is less than the standard voltage. Measure the resistance between the terminals of the generator 3P connectors
(
and
) according to the table below.
Generator
Master
Slave
If the resistance is out of the specification, check the stator coil resistance
according to the table below.
Terminal
Stator
number
N 1 - U 1
Master
N 1 - V 1
N 1 - W 1
N 2 - U 2
Slave
N 2 - V 2
N 2 - W 2
If all resistances are OK, replace or repair the generator wire harness.
If the resistance is out of specification, replace the stator.
Date Revised: March 2021 (PSV52522-S)
© 1998-2021 American Honda Motor Co., Inc.—All Rights Reserved
and
) with the generator mounted.
Connector
Terminal number
Connector
Terminal number
Standard
resistance
0.22 - 0.31 Ω
0.22 - 0.31 Ω
Specific voltage
1 - 2
2 - 3
AC 15 V or more
1 - 3
1 - 2
2 - 3
AC 15 V or more
1 - 3
Standard resistance
1 - 2
2 - 3
0.44 - 0.62 Ω
1 - 3
1 - 2
2 - 3
0.44 - 0.62 Ω
1 - 3
N 2
N 1
W 2
V 2
U 2
U 1
V 1
W 1