SERVICING YOUR GENERATOR
Battery Inspection
The electrolyte level must be kept between the UPPER and LOWER
level marks. If the electrolyte level is below the LOWER level, sulfation
and battery plate damage will occur.
If rapid loss of electrolyte is experienced, or if your battery seems to be
weak causing slow operation of the starter motor, see your authorized
Honda generator dealer.
1.
Locate the battery. Check the electrolyte level with the generator on
a level surface. Remove the battery cell caps.
2.
Inspect the electrolyte level of each cell.
The electrolyte level must be kept between the UPPER and LOWER
level marks, and electrolyte liquid should cover all the plates.
3.
If any plates are not covered, remove the battery and add distilled
water as necessary.
BATTERY
56
BATTERY CELL CAPS
UPPER LEVEL
LOWER LEVEL