Typical Pit Plan - Presto Lifts ECOA PDL60-50 Owner's Manual

Hide thumbs Also See for ECOA PDL60-50:
Table of Contents

Advertisement

4.3

Typical Pit Plan

3" X 3" X 1/4" ANGLE BY
PIT CONTRACTOR. ALL
CORNERS TO BE
SECURELY WELDED. PIT
MUST BE SQUARE ( 1/2")
ACROSS CORNERS.
PLATFORM
WIDTH
+1-1/2"
Ø3/4" LAG HOLES FOR
Ø5/8" ANCHORS WITH
MIN. 2000 LB PULL
OUT. (BY INSTALLER)
CROSS HATCHING INDICATES AREAS OF
BASE FROM THE MUST BE SHIMMED AND
OR GROUTED AFTER LEVELING OF THE
BASE FRAME TO ENSURE PROPER BASE
FRAME SUPPORT.
CONDUIT RUN IS REQUIRED FOR ROUTING
OF HYDRAULIC HOSES AND ELECTRICAL
WIRING UNLESS ALTERNATIVE
ARRANGEMENTS ARE REQUESTED.
2" ELECTRICAL CONDUIT USED WHEN 1/2"
HYDRAULIC HOSE, VENT LINE, AND
ELECTRICAL LEADS ARE TO BE INSTALLED
FROM POWER UNIT TO LIFT (BY PIT
CONTRACTOR).
CONCRETE ANCHORS TO
BE
1/2" X 6" LOCATED
12" O.C. WITH ONE 3"
FROM EACH END.
CONCRETE BEHIND CURB
ANGLES MUST BE WELL
COMPACTED WITH NO
VODIS
1/2" SHIM
UNDER EACH
LAG PLATE FOR
PROPER DRAINAGE
Presto Lifts
CONDUIT ENTRY CAN BE
FROM ANY DIRECTION
INCLUDING ENTRY FROM
BOTTOM OF PIT SUMP.
COUPLINGS FOR
HYDRAULIC
CONNECTIONS
PLATFORM LENGTH + 1-1/2"
6"
3"
10
2" CONDUIT
1 1/2"
CENTER LINE OF
BOLLARDS TO BE
ALIGNED WITH
FRONT OF PIT
PIT DRAIN AS REQUIRED TO
PREVENT STANDING WATER
IN PIT. (BY CONTRACTOR)
STEP REQUIRED FOR BRIDGE
PLATE HINGE CLEARANCE
BRIDGE
PLATE
WIDTH
+1/2"
BRIDGE PLATE
LENGTH + 1/2"
8" BOLLARDS
STEEL PIPE FILLED
WITH CONCRETE
(BY CONTRACTOR)
48"
1/2"
LOW
HEIGHT
36"
+1/2"
PDL Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecoa ddl60-60Ecoa pdl60-80

Table of Contents