MAHLE ACX380 Service Manual page 43

Table of Contents

Advertisement

en
43 | ACX380/480 |
CODE
MESSAGE
A039
FURTHER OIL INJECTION NOT
POSSIBLE
A040
FURTHER UV DYE INJECTION
NOT POSSIBLE"
A043
VESSEL FULL
A044
REFRIGERANT ANALYZER
NOT WORKING
A045
REFRIGERANT ANALYSIS
FAILED
A046
REFRIGERANT ANALYZER
MODEL NOT SUPPORTED
A047
LP LEAKAGE
A048
HP LEAKAGE
A049
LP AND/OR HP LEAKAGE
A051
RECOVERED REFRIGERANT
AMOUNT TOO HIGH
A056
REFRIGERANT ANALYSIS
NEGATIVE
A057
REFRIGERANT PRESSURE IS
TOO LOW IN ORDER TO
PERFORM THE ANALYSIS
A058
REFRIGERANT ANALYZER
VERIFICATION NEGATIVE
When it occurs
Possible situations
During oil injection
Insufficient vacuum level
phase
During the UV dye
Vacuum not enough to
injection phase
inject UV dye
During the gas recovery
Internal tank full,
and hoses emptying
maximum capacity level
phase
reached
During gas recovery,
Identifier wrongly
hoses emptying, bottle
connected or
filling, refrigerant
malfunctioning.
analyzer check
During the refrigerant
analysis phase
During use of analyzer
Model not supported.
During the gas recovery
At the end of the gas
and hoses emptying
charging, in the E3
phase
Connect quick coupler
disconnection phase
during the vehicle
fittings leak test
During the gas recovery
At the end of the gas
and hoses emptying
charging, in the E3
phase
Connect quick coupler
disconnection phase
during the vehicle
fittings leak test
During the gas recovery
At the end of the gas
and hoses emptying
charging, in the E3
phase
Connect quick coupler
disconnection phase
during the vehicle
fittings leak test.
During the gas recovery
Possible scale
phase
calibration problem
During the refrigerant
analysis phase
During the refrigerant
Low pressure inside A/C
analysis phase
system under test.
Identifier hose filter
clogged
During the refrigerant
analysis phase
Possible solutions
Increase the vacuum phase
time, check the A/C system
tightness.
Increase the vacuum phase
time, check the A/C system
tightness.
Decrease quantity of gas by
filling (charging) an external
tank rated for R134a (with
safety valve)
Check the connections and
make sure that the identifier
led is on, then repeat the
procedure
Check with virgin refrigerant
bottle if the refrigerant gas
identifier is working properly. If
yes and the refrigerant of the
car is not R1234yf, empty in a
safety way and in compliance
with environmental laws, the
mobile air conditioning system
of the vehicle.
Change analyzer model.
Empty the vehicle (follow the
procedure guided by the
displayed messages)
Empty the vehicle (follow the
procedure guided by the
displayed messages)
Empty the vehicle (follow the
procedure guided by the
displayed messages)
Carry out scale calibration
check
Check with virgin refrigerant
bottle if the refrigerant gas
identifier is working properly. If
yes and the refrigerant of the
car is not R1234yf, empty in a
safety way and in compliance
with environmental laws, the
mobile air conditioning system
of the vehicle.
Check the presence of the
refrigerant.
Check or change the
filter/hose of the identifier
Check with virgin refrigerant
bottle if the refrigerant gas
identifier is working properly. If
yes and the refrigerant of the
car is not R1234yf, empty in a
safety way and in compliance
with environmental laws, the
mobile air conditioning system
of the vehicle.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acx480

Table of Contents