Appendix 3 - Acx380/480 - Electrical Connection - Logic Electronic Board - MAHLE ACX380 Service Manual

Table of Contents

Advertisement

APPENDIX 3 – ACX380/480 - ELECTRICAL CONNECTION – LOGIC
ELECTRONIC BOARD
Item
label
1)
FAN
Tachometric fan connector
2)
SER I/O
serial I/O interface to power board
3)
PAR I/O
parallel I/O interface (not used)
4)
SER AUX
refrigerant gas identifier serial interface
5)
PRN
thermal printer serial interface (power and communication)
6)
LC Tank
input load cell tank
7)
LC Dye2
input load cell dye 2
8)
LC New
input load cell new oil 2
Oil2
9)
LC Dye1
input load cell dye 1
10)
LC New
input load cell new oil 1
Oil1
11)
PS Tank
input pressure sensor tank
12)
LC Ex.Oil
input load cell
13)
PS LP
input pressure sensor LP
14)
PS HP
input pressure sensor HP
15)
TS Tank
input temperature sensor refrigerant tank/cylinder
16)
TPSW 1
input anti-tamper switch
17)
TPSW 2
input anti-tamper switch
18)
TPSW 3
input anti-tamper switch
19)
USB0 = USB port for BSP programming of MCU (only for production operations)
20)
PCAP
LCD touch screen interface
21)
KYB
matrix keyboard interface
22)
Lithium RTC battery CR2032 3V
23)
USB Service (only for production operations)
24)
Recovery button = programming BSP of MCU
25)
LCD
LCD interface
26)
BKL
LCD backlight supply connector
Description
| ACX380/480 | 36
en
Connected ( ) Unused (x)
X
optional
X
X
X
X
X
X
X
X

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acx480

Table of Contents