5

Technical features

Cylinders for R134a or R1234yf
R134a or R1234yf
cylinder capacity
Maximum
operating
pressure (PS)
PED category
(Dir.2014/68/EU)
Weight of
refrigerant content
Safety valve
Type
Calibration
pressure
PED category
(Dir.2014/68/EU)
Containers for oil and detection dye
Recovered PAG
oil container
New PAG oil
container
UV Dye container
New POE oil
container
Pneumatic circuit
Vacuum pump
flow rate
Vacuum level
Vacuum pump oil
life
Refrigerant
recovery
compressor cubic
capacity
Drier filter
Non condensable
gas discharge
HP and LP taps
Safety pressure switch
Type
Trip pressure
PED category
(Dir.2014/68/EU)
Pneumatic fittings
Net length of
external HP and
LP hoses
HP and LP
fluids
20 l
20 bar
III
Scale
AIRTEK -
VS14NPT20HN
BRPED4 20bar
R 1/4 NPT
20 bar
IV
250 ml
250 ml
250 ml
250 ml
100 l/min double
stage
0.02 mbar
60h – extensible
to max 1000 h
with E
3
PUMP
procedure
14 cc
Every 150Kg of
refrigerant
recovered
Automatic, with
solenoid valve
Automatic
13/18bar
1/4SAE
18 bar
IV
4.5 m
Analog 80 mm,
| ACX380/4850 | 10 en
pressure gauges
pulse-free, 1.0
Display
Touch screen
7" TFT colours
Keypad
Touch screen
Software updating
Via Wi-Fi
Printer
via Nexusprint
software or via
thermal printer
Functions and features
Recovered oil
Automatic
measurement
weighing, 1 g
res., 5 g acc.
New oil automatic
With automatic
charge
scale, 1 g res.,
5g acc.
UV dye automatic
Timed
charge
Electric
With integrated
compressor
flushing function
function
Flushing
Flushing
available with
external
accessory
(option)
Database
Complete
electronic (cars
and industrial
vehicles only)
AC Performance
Manual and
Test
automatic
Recovered oil
Automatic
measurement
weighing, 1 g
res., 5 g acc.
Sound level
< 70 dB (A)
Battery type for
Lithium CR-
internal Real time
2032 3V
clock
180mAh 3g.
Overall dimensions
WxDxH
700 x 750 x
1100 mm
Loadless weight
about 85 kg
Power supply
Frequency
50 Hz
Voltage
230 V ~
Power
800 W
Protection
Thermal
Installation
category
Environmental conditions
Operating
10-50°C
temperature
Humidity
10-90% R.H.
condensing)
Ambient pressure
75 kPa until 106
class
II
(non
kPa