9 Service Menu

To carry out calibration the service kit (tooling set)
calibration the service kit (tooling set)
described at chapter 10 is required.
9.1
Manual activations and analogue
Manual activations and analogue
channel view
From the SECURED SERVICE menu, (insert the password
SERVICE menu, (insert the password
select MANUAL ACTIVATIONS and press
MANUAL ACTIVATIONS and press
"DEBUG"),
START, insert the password "DEBUG", press RETURN and
then enter OK.
This submenu allows controlling the actuators and displays
This submenu allows controlling the actuators and displays
all measurements.
Fig. 15: Manual activations screen
As shown in the picture the activated actuators are
highlighted with
green
background colour. If deactivated
background colour. If deactivated
the colour is red.
The corresponding chart can be found in the APPENDIX
At the bottom you can select the following functions:
At the bottom you can select the following functions:
Pneumatic schema
Screen rotation (useful if the front door is open)
Screen rotation (useful if the front door is open)
Close menu
(red
square)
Manual Activation Key
Actuators of
(in bold the names
the Pneumatic
used in this manual)
Schema (see
APPENDIX 1)
A-S13
A1, A2
R-S10
R1, R2
L-S62
L1
T-S61
T1
S-S60
S
I-S15
I
N-S8
N
V1-N3
V1, V2, V
C-N1
C
L2
L2
H
H
N IN
X
N OUT
T2
© MAHLE
9.2
From the SECURED SERVICE menu, (insert the password "DEBUG"),
select PRESSURE CALIBRATION and press START
messages, and enter OK to confirm.
Disconnect the LP and HP quick couplers from any A/C system and
Disconnect the LP and HP quick couplers from any A/C system and
press enter OK.
Wait some minutes until the sentence "Emptying hoses" di
Then the message asks to connect to LP hose the
adapter (alone, not connected to the bottle)
station accessories kit; when the next message is displayed,.
station accessories kit; when the next message is displayed,.
RETURN and
Fig. 16: LP quick coupler opening
Turn the LP quick coupler clockwise to open it and press enter OK
so that air gets into the LP hose
Wait for the message to connect the reference gauge contained in
Wait for the message to connect the reference gauge contained in
the service kit and, by rotating LP counter clockwise, close and
remove the bottle fitting adapter.
WARNING:
BE SURE BEFORE TO CONFIRM, THAT BOTTLE FITTING
BE SURE BEFORE TO CONFIRM, THAT BOTTLE FITTING
ADAPTER HAS BEEN REMOVED FROM LP QUICK COUPLER.
ADAPTER HAS BEEN REMOVED FROM LP QUICK COUPLER.
Connect to HP coupler the reference gauge present in the SERVICE
KIT, open the HP quick coupler by rotating it clockwise and press
APPENDIX.
enter OK.
WARNING:
ATTENTION NOT TO POINT THE REFERENCE
ONESELF OR OTHER PEOPLE UNTIL ONE HAS THE ABSOLUTE
ONESELF OR OTHER PEOPLE UNTIL ONE HAS THE ABSOLUTE
CERTAINTY THAT THE CONNECTION WITH THE QUICK COUPLER
IS SAFE.
Power Board
Power Board
Output (see
(see
OPEN THE TAP OF THE QUICK COUPLER BY POINTING THE
OPEN THE TAP OF THE QUICK COUPLER BY POINTING THE
APPENDIX
APPENDIX 4)
GAUGE TOWARDS THE GROUND, ALWAYS KEEP THE GAUGE
TOWARDS
TOWARDS
OUT A
PROCEDURE REQUIRES ENTERING THE VALUE DISPLAYED ON
PROCEDURE REQUIRES ENTERING THE VALUE DISPLAYED ON
OUT R
THE SAMPLE GAUGE.
OUT L1
OUT T1
OUT S
OUT I
OUT N
OUT V
OUT C
OUT L2
OUT H
Fig. 17: Reference gauge connection
OUT X
OUT T2

Pressures calibration (service kit)

calibration (service kit)
some minutes until the sentence "Emptying hoses" disappears.
connect to LP hose the bottle fitting
(alone, not connected to the bottle), included in the ACX
k coupler clockwise to open it and press enter OK
and, by rotating LP counter clockwise, close and
P quick coupler by rotating it clockwise and press
CONNECTION WITH THE QUICK COUPLER
THE
THE
GROUND
GROUND
EXCEPT
EXCEPT
| ACX380/480 | 15
en
(insert the password "DEBUG"),
and press START, read the
gauge present in the SERVICE
REFERENCE GAUGE TOWARDS
ALWAYS KEEP THE GAUGE
WHEN
WHEN
THE
THE
GUIDED
GUIDED
Fig. 18:
: Reference gauge reading