Connecting The Power Supply - Siemens SIMOTION SCOUT D410 Manual

Hide thumbs Also See for SIMOTION SCOUT D410:
Table of Contents

Advertisement

5.5

Connecting the power supply

The 24 V DC load power supply required for the supply must be wired to the screw terminal
block (connector X124).
Note
The interface X124 is provided exclusively to connect the external power supply.
Properties of the load power supply
The 24 V DC voltage must be generated as functional extra-low voltage with safe electrical
isolation (according to IEC 204-1, Chapter 6.4, PELV) and grounded by the user (establish
a connection between PELV signal M and central grounding point of the system).
Table 5- 5
Parameters
Voltage range - mean value
Ripple
Transient overvoltage
Rated current consumption
Starting current
Power consumption
D410
Manual, 05/2009
DANGER
Electrical parameters of the required load power supply
Values
Conditions
20.4...28.8 V DC
max. 5 %
at 24 V DC
max. 35 V DC
Max. 500 ms, 50 s recovery time, max.
10 results/h.
0,8 A
Without DRIVE-CLiQ and digital outputs
3 A
Without power module, DRIVE-CLiQ and
digital outputs
20 W
Connecting
5.5 Connecting the power supply
65