Page 5
MR16 User’s Manual V1.1 12V 5000mA Power Supply HDMI GPIO (Support 2 path input photocoupler and 2 path output photocoupler with isolation.) UHF antenna port, SMA female*8 USB port, used to connect mouse and others, touch-screen function supported. Dial *#*#555666#*#* to enter engineer mode.
MR16 User’s Manual V1.1 1.3 Accessory List Item Remark MR16 reader, 12V power adaptor & Power Cable Out of Box UHF antenna, 6dBi, 9dBi, 12dBi etc. (Optional) Sold Separately Feeder line, SMA male side connects with device, Not included. interface on other side needs match with antenna.
MR16 User’s Manual V1.1 1.4 Device installation MR16 reader adopts Android operating system, it can be connected with Internet through RJ45, WIFI and 4G etc. And connect with monitor through HDMI cable. Developer could use USB cable to connect device with PC for developing application, device could also be connected with PC through serial port cable.
Page 10
MR16 User’s Manual V1.1 Connect monitor through HDMI cable and long-press power button for 3 seconds to switch on device. Click demo_uhf icon to enter demo as Pic.4-1, UHF module will initiate as Pic.4-2, if there is no error messages show up, then initiation process has been successfully finished.
MR16 User’s Manual V1.1 Chapter 3 UHF tag scanning Click SCAN on top of navigation bar to enter tags reading page. 3.1 Auto Scanning Select “Auto”, then click “Start” button to start tags scanning circularly, the information such as EPC or TID, Count, RSSI and Ant.
MR16 User’s Manual V1.1 3.2 Single Scanning Select “Single” button and click “Start” to start scanning tag, EPC or TID, Count, RSSI and Ant.number will display on right side, as Pic.5- Pic.5-3...
MR16 User’s Manual V1.1 3.3 Read UHF Tag Click “READ” on top of navigation bar to enter page of tag reading. User could read data of 4 areas, RESERVED, EPC, TID and USER, setup address and data length, default password is “00000000”, click “Read”...
Page 15
MR16 User’s Manual V1.1 Comment: user could filter tags by setup address, data length and data in EPC, TID and USER areas, select “Enable” button to switch on filter function in Pic.6-2. Pic.6-2...
MR16 User’s Manual V1.1 3.4 Write Tag Click “WRITE” on top of navigation bar to enter tag writing page. User could write data in RESERVED, EPC, TID and USER areas, setup start address and data length, input access password and data(hex), click “Write Data”...
MR16 User’s Manual V1.1 3.5 Lock Tag Click “LOCK” on top of navigation bar to enter tag locking page. Input access password( DONOT input default password.), then click column of “Lock Code”, it will display window for selecting different methods of locking, click “OK” to generate lock code automatically, then click “Lock”...
MR16 User’s Manual V1.1 3.6 Kill Tag Click “KILL” on top of navigation bar to enter operating page. Input access password (DONOT input default password.), click “Kill” button to destroy tags in Pic.9-1. Comment: user could filter tag by setup address, data length and data for selecting EPC, TID or USER area.
MR16 User’s Manual V1.1 3.7 UHF Module Version Click 3 dots on top right of application and click “About” in list to check version of UHF module in Pic.10-1. Pic.10-1...
MR16 User’s Manual V1.1 3.8 Module Temperature Click 3 dots on top right of application, click “Module temperature” in list to check UHF module temperature in Pic.11-1. Pic.11-1...
MR16 User’s Manual V1.1 Chapter 4 Config Click “CONFIG” on top of navigation bar to enter setup page. 4.1 Working mode User could setup different frequency band for different countries, as Pic.12-1, click “Set Frequency” to confirm frequency band. Click “Get Frequency”...
MR16 User’s Manual V1.1 4.2 Output Power User could select different output power from 5 to 30dBm in Pic.12-2, click “Set Power” to confirm setup. Click “Get Power” to get current output power. Pic.12-2...
MR16 User’s Manual V1.1 4.3 R2000 settings Select ANT1-ANT8 to setup antenna, selected antenna will start functioning, unselected antenna will in OFF in Pic.12-3. Click “Set Antenna” to confirm setup, “Get Antenna” to check current antenna status. Pic.12-3...
MR16 User’s Manual V1.1 4.5 RF link There are four parameters can be selected in this parameter, as Pic.12-5. Click “Set link parameter” to confirm, click “Get link parameters” to check current RF link parameters. Pic.12-5...
MR16 User’s Manual V1.1 4.6 QT Tag Select “Set QTPara” to switch ON and OFF hidden areas of QT tag, click “Get QTPara” to check current status. Pic.12-6...
MR16 User’s Manual V1.1 4.7 Open tagFocus Select ON/OFF of tagFocus in Pic.12-6. 4.8 Open FastID Select ON/OFF of “Open the EPC and TID” in Pic.12-6. 4.9 Open EPC and TID Select ON/OFF of “Open the EPC and TID” in Pic.12-6.