5.2
Before you install the oxygen generator, and oxygen receiver, if supplied, refer to
the Specifications section in Appendix A of this instruction manual to determine
applicable floor space, feed air, and power requirements for your particular model.
5-2

Pre-installation Guidelines

The oxygen generator may use feed air at specifications outside
those shown in Appendix A of this instruction manual; however,
use of such feed air may require modification of the oxygen
generator at the AirSep Corporation factory to ensure the
product oxygen meets the specifications shown in Appendix A.
Consult your sales representative to determine whether your
oxygen generator requires modifications for your application.
Locate the oxygen generator in an area where the ambient air
temperature remains between 4
prevent damage not covered under the AirSep Corporation
Product Warranty.
To prevent fire or electrical shock, locate the oxygen generator
away from rain or any other type of moisture.
Make sure the area that surrounds the oxygen generator is well
ventilated, and provide sufficient space around the unit [at least
one meter (three feet)] to allow for cool air flow as well as to
allow safe operation and maintenance.
AirSep oxygen generators are sold for use in industrial
applications only. Contact AirSep Corporation or an authorized
AirSep representative before you use this unit for any medical
application.
AirSep
°
°
°
C (40
F) and 44
C (111
AS-20—1000 Instruction Manual
®