Lotus CPA-94ETT Installation And Operating Instructions Manual

Electric pasta cookers

Advertisement

Quick Links

Installation and operating instructions
ELECTRIC PASTA COOKERS FOR
PROFESSIONAL USE
CPA-94ETT CPA-98ETT
Model LIBR.ISTR.S90D CPA-ETT
Code 5630604A0
Review 1
Edition date 12/11/2024
Language English
LOTUS S.p.A.
Via Calmaor, 46
31020 San Vendemiano
+39 0438 778020
+39 0438 778277
Translation of the original instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CPA-94ETT and is the answer not in the manual?

Questions and answers

Summary of Contents for Lotus CPA-94ETT

  • Page 1 Installation and operating instructions ELECTRIC PASTA COOKERS FOR PROFESSIONAL USE CPA-94ETT CPA-98ETT Model LIBR.ISTR.S90D CPA-ETT Code 5630604A0 Review 1 Edition date 12/11/2024 Language English LOTUS S.p.A. Via Calmaor, 46 31020 San Vendemiano +39 0438 778020 +39 0438 778277 Translation of the original instructions...
  • Page 2: Table Of Contents

    Contents Contents INTRODUCTION ......................... Installation drawing ........................Example installation of the appliance................... GENERAL INFORMATION......................Declaration of compliance......................User information, RAEE Directive on waste electrical and electronic equipment ......Technical data table ........................INSTALLATION........................... Delivery checks ..........................Removing the packaging ......................Mechanical installation .........................
  • Page 3: Introduction

    INTRODUCTION 1 INTRODUCTION Installation drawing FIG. 1 CPA-94ETT CPA-98ETT A Data Plate B Electrical connection D Water connection R 3/4"M E Water drain R 1"M F Energy saving connection   Translation of the original instructions...
  • Page 4 INTRODUCTION FIG. A WIRING DIAGRAM CPA-94ETT CPA-98ETT 400V~3N 50/60 Hz Translation of the original instructions...
  • Page 5 Water safety control unit Jack socket single-pole switch Water sensor K-type thermocouple temperature probe TP1000 temperature probe   MODELS FIG.A CPA-94ETT CPA-98ETT A + A   FIG. B (ROTARY RESISTANCE) 1 O-rings 2 Rotary heating element   Translation of the original instructions...
  • Page 6: Example Installation Of The Appliance

    INTRODUCTION Example installation of the appliance Translation of the original instructions...
  • Page 7: General Information

    GENERAL INFORMATION 2 GENERAL INFORMATION Declaration of compliance The manufacturer declares that the appliances comply with the requirements of the regulation GAR 2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be performed in compliance with current regulations, especially with regard to ventilation of the premises and the exhaust gas evacuation system.
  • Page 8: User Information, Raee Directive On Waste Electrical And Electronic Equipment

    Technical data table Technical data table CPA S90ETT MAXIMUM MAXIMUM POWER CABLE MODEL DIMENSIONS POWER SUPPLY ABSORPTION POWER (kW) silicon type CPA-94ETT 40x90x90h 400V~3N 50/60 Hz 19,57 13,5 5 x 2,5 mm² CPA-98ETT 80x90x90h 400V~3N 50/60 Hz 39,13 5 x 6 mm²...
  • Page 9 GENERAL INFORMATION Table of parameters CPA-9..ETT PARAMETER Adjustment ID code DESCRIPTION U.M. Resol. field MAX temp. Maximum temperature 50 - 400 °C NTC temperature for cooling Fan temp. setting 0-50 °C fan(s) start-up Enabling of instrument compartment cooling fan(s) start-up: Cooling fan 0=always off 1=always on...
  • Page 10 GENERAL INFORMATION PARAMETER Adjustment ID code DESCRIPTION U.M. Resol. field Calculation limit of the PID KI constant. % referring to the PID TR (15) and defines the   MaxOut PID_I maximum value of the ON time 20 - 80 component, calculated from the Integrative component alone.
  • Page 11: Installation

    INSTALLATION 3 INSTALLATION Delivery checks On delivery, it is important to check the following:   · External conditions of the packaging · The general status of the equipment · The conformity of the model with the information in the technical data plate and the instruction manual ·...
  • Page 12: Electrical Connection

    INSTALLATION Warning Installation operations, any conversion to other types of gas and start-up must only be performed by qualified personnel, in accordance with current regulations.   Gas systems, electrical connections and premises where the appliances are installed must comply with current regulations in the country of installation;...
  • Page 13: Water Connection And Drainage

    INSTALLATION Caution ALL PARTS THAT GIVE ACCESS TO LIVE PARTS AFTER REMOVAL ARE MARKED WITH THE "WARNING: DANGEROUS VOLTAGE" SYMBOL     Water connection and drainage · It is advisable to connect the appliance to the hot water pipe (max. 60 °C) to reduce heating times; we also recommend installing a shut-off valve up-line of the appliance ·...
  • Page 14: Instructions For Use

    INSTRUCTIONS FOR USE 4 INSTRUCTIONS FOR USE General information This appliance must only be used for its expressly intended purpose for cooking or heating food. Any other use is considered improper. The appliance is also intended for industrial use and must only be used by personnel trained for use and aware of the risks that the hot element entails.
  • Page 15: Emptying The Tank

    INSTRUCTIONS FOR USE Emptying the tank To perform this operation, open the drain tap (lever in vertical position) which can only be reached from the door of the cabinet underneath the appliance   Note It is advisable to perform this operation using water that is not excessively hot  ...
  • Page 16: Maintenance

    MAINTENANCE 5 MAINTENANCE Routine When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation. We therefore recommend stipulating a service contract.   Caution Maintenance must only be performed by specialist personnel in compliance with current regulations and our own instructions.
  • Page 17 MAINTENANCE Warning MEASURES TO BE TAKEN IF THE APPLIANCE IS NOT TO BE USED FOR A LONG TIME: Close the gas cock and/or disconnect the power supply. Clean the system as specified above. Translation of the original instructions...
  • Page 18: Cleaning

    CLEANING 6 CLEANING Routine cleaning Caution The use of flammable fluids to clean the appliance is forbidden   To ensure hygiene and the durability of the appliance, perform external cleaning on a regular basis, taking care not to damage the cables and the electrical connections. Before starting cleaning, disconnect the appliance from the power supply.

This manual is also suitable for:

Cpa-98ettLibr.istr.s90d cpa-ett

Table of Contents